TFxB Series Thermostat Controller
®
BACnet
Communication Module

User Guide

TFxB-SERIES-BACNET-USER GUIDE
TFxB24-Bacnet-121026-EUA.doc

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TFCB24F3XYZ1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Neptronic TFCB24F3XYZ1

  • Page 1: User Guide

    TFxB Series Thermostat Controller ® BACnet Communication Module User Guide TFxB-SERIES-BACNET-USER GUIDE TFxB24-Bacnet-121026-EUA.doc...
  • Page 2: Table Of Contents

    Table of Contents TFxB Series Thermostat Controller ..................1   Table of Contents ........................1   Introduction ..........................2   ® BACnet Overview ........................2   Getting Started ......................... 3   Quick Setup ..........................3   Manual Setup .......................... 3  ...
  • Page 3: Introduction

    Alarms Although the thermostat controller supports the ability to indicate various alarm conditions through value ® changes in properties of several of its objects, it does not generate BACnet Event Notifications. Features Neptronic thermostat controllers also offer the following time-saving features.
  • Page 4: Getting Started

    ® The following BACnet properties are configurable and may need to be modified to effectively establish ® communication on the network and to guarantee uniqueness of each device in a BACnet system.  MAC Address (Default: 001) Set between 000 and 254 via thermostat menu* (128-254 represent MS/TP non-token-passing slave devices).
  • Page 5: Copy Config

    MS/TP units on the ® MS/TP network. Some MAC address and Max_Master combinations are more efficient than others. BACnet requires token-passing units to occasionally “poll” for other masters based on the MAC address and Max_Master.
  • Page 6: Device Object Properties

    (3) = No Segmentation APDU_Timeout 3000 Number_of_APDU_Retries Always 0 ® Protocol_Services_Supported Always 0x00 0x09 0x40 0x00 0x60 (i.e. a bitstring in BACnet order) Protocol_Object_Types_Supported Always 0x00, 0xB4, 0x80, 0x10 ® (i.e. a bitstring in BACnet order) - analog-input, analog-value, binary-input, binary-value...
  • Page 7: Object Types Supported

    ® The Device Object has already been described. The following tables list all the BACnet properties supported for each object type. Most of the properties are locked in. The exception is Present_Value, which represents the dynamic operating values of the device, and the Status_Flag, Event_State and Reliability properties which reflect the availability of the Present_Value.
  • Page 8: Objects Table

    TFxB Series Thermostat Controller Objects Table ® ® The TFxB24 Thermostat series of controllers use the following BACnet object table. The type is the BACnet ® ® Object type, the instance is the BACnet Object. Together the type and instance form the BACnet Object_Identifier for an object according to the following C-language algorithm: ...
  • Page 9 TFxB Series Thermostat Controller Writable Name Notes Property 0= Open BI.1 DigitalInput Out of service x x x x x x x 1= Close 0= Celsius BV.1 Temper.Unit Present Value x x x x x x x 1= Fahrenheit 0= Disable BV.2 Temper.SetPointLock Present Value...
  • Page 10 TFxB Series Thermostat Controller Writable Name Notes Property States of all except TFxB24-OEy States available if MSV.4 is set to “Auto” 1= Auto 2= Heating 3= Cooling 4= Off (only if BV.3 is set to “Enable”) States available if MSV.4 is set to “Cooling” 1= Cooling 2= Off (only if BV.3 is set to “Enable”) States available if MSV.4 is set to “Heating”...
  • Page 11 TFxB Series Thermostat Controller Writable Name Notes Property 1= OccNorm.Open MSV.11 DigitalInputMode Present Value x x x x x x x 2= OccNorm.Close States available if BV.5 is set to 2Pipe: 1= ChangeOverSensor 2= Ch.Ov.ContactNorm.Cool 3= Ch.Ov.ContactNorm.Heat States available if BV.5 is set to 4Pipe except MSV.12 UniversalInput2Function Present Value...
  • Page 12 400 Lebeau Blvd, Montreal, Qc, H4N 1R6, CANADA www.neptronic.com Toll free in North America: 1 800 361-2308 Tel.: (514) 333-1433 Fax: (514) 333-3163 Customer service Fax: (514) 333-1091 Business hours: from Monday to Friday, 8:00am to 5:00pm (Eastern time)

Table of Contents