7. Raise and carefully turn the pipe sections required for connecting to the exte-
rior unit and route them through the Ø 70 mm hole.
8. Route the condensation drain pipe through the same hole. Depending on per-
sonal requirements, this pipe can also be routed in other directions, so long as it
slopes sufficiently to allow the condensation to drain away properly.
9. Hang the interior unit securely on the hooks of the fixing plate.
10. Make sure that the unit has been firmly fixed by moving it towards the right
and left.
NOTE: To make it easier to fix the unit to the plate, keep the lower part of the unit
raised then lower it perpendicularly into position, accompanying the sheath as
this is done (Fig.3).
The installer's experience will allow all these operations to be perfected to suit the
specific requirements.

OTHER POSITIONS FOR INSTALLATION

The unit can also be installed in the following positions:
1. With outlet at the rear left
2. With outlet at the side, on the left
3. With outlet at the side, on the right
4. With outlet pointing downwards
Proceed as indicated below to install the unit with the outlets at the rear left:
1. Make the Ø 70 hole near the left-hand outlet.
2. Make the wet connections between the pipes of the interior unit and those of
the exterior unit.
3. Position the pipes in the housing in the interior unit and fix them in place with
the relative plate as shown in the figure alongside (Fig.5).
Proceed as described below to install the unit with outlets at the side or pointing
downwards:
1. Detach the pre-cut plate (Fig.6) from the direction required.
2. Turn the pipes carefully to the required direction.
3. Make the cooling pipe connections between the pipes of the interior unit and
those of the exterior unit.
10
MACHINE INSTALLATION
Fig.3
Fig.4
Fig.5
Fig.6