Installation

Installation Warnings

! Failure to follow all of the requirements may result in property damage, bodily injury, or even death.
! This heater must be installed by a qualified installer who has gone through a training program for the
installation of direct vent gas appliances.
! This appliance must be installed in accordance with all local codes, if any; if not, follow current ANSI
Z223.1 or NFPA 54.
! In Manufactured or Mobile Homes this appliance must be installed to the applicable Mobile Home
Standards: Title 24 CFR, Criteria for Manufactured Home Installations, Sites and Communities, and/or
ANSI/NFPA 501A. This appliance may be installed in Manufactured Housing only after the home is site
located.
! This appliance is designed for natural gas or propane (LP). Check the sticker on top of the gas control
valve.
! All exhaust gases must be vented outside the structure of the living-area. Combustion air is drawn from
outside the living-area structure.
! Notify your insurance company before hooking up this appliance.
! The requirements below are divided into sections - all requirements must be met simultaneously.

Packing List

• Log Set with Coals

Installation Preparation

HINT:
If converting to LP, convert the appliance prior to installation.
HINT:
Install the logs last - they are fragile.
HINT:
When determining the location of the stove, locate the wall studs (for horizontal penetrations)
and ceiling trusses (for vertical penetrations). You may wish to adjust the stove position
slightly to ensure the vent does not intersect with a framing member.
HINT:
Fumes and smoke from the paint curing and oil burning off the steel may occur the first time
you start this heater. This is normal. We recommend you open windows to vent the room.
Stove
Clearances
Mobile Home
Requirements
Travis Industries
(for qualified installers only)
• Propane Conversion Kit
Straight Installations
10" Min.
100-01135
• Latch Tool
Corner Installations
With this clearance, the vent is
centered 15-1/8" from the wall.
4" Min.
7
4 0 4 0 8 0 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Heritage ef iii

Table of Contents