Check all hoses and clamps for damage or
looseness.
The image only shows some of the hoses and clamps.
Look for leakage on fuel, hydraulics and cooling system.
Tighten or replace as necessary.
Check air cleaner restriction indicator.
Check and clean the outer air filter if the air cleaner
indicator is red, remove the rear cover by opening the 3 air
filter housing clamps and pulling the housing off.
Clean the filter by blowing the element from inside out.
Use the lowest possible air pressure to remove the dust
without damaging the element.
Use 42-47 PSI (0,29-0,49 MPa;3,0-5,0 kgf/cm
compressed air to remove particulates.
MAINTENANCE AND SERVICE
2
)
Replace any damaged filters or gaskets and check air
hose and clamps for damages or looseness. Tighten or

replace as required.

NOTICE! No need to clean the inner filter on a daily basis.
The 3 air filter housing clamps can not be closed unless the
outer air filter is properly installed.
Protection covers
Make sure all protection covers are in place and in good
condition.
For more information, see the "Machine's safety equipment"
section.
Drain cooling water from gearbox to prevent rust
and/or freeze damage.
To drain water from gearbox, turn the drain tap
counterclockwise to open and clockwise to close.

Check the water spray over the diamond blade.

Raise blade guard front and use quick release pin to lock
it in upright position.