Electrical system
Remove the protective base from the connector.
With the ignition key switch at ON check there is
battery voltage between the Red-White and Black
cables
With MIU connector disconnected check the con-
tinuity between the Orange-White cable and pin 7
of the interface wiring .
Specific tooling
020481Y Control unit interface wiring
020331Y Digital multimeter

Virgin circuit

When the ignition system is not encrypted, any key will start the engine but limited to 2000 rpm. The
keys can only be recognised if the control unit has been programmed properly. The data storage pro-
cedure for a previously not programmed control unit provides for the recognition of the master as the
ELE SYS - 18