Arm/Disarm Diagnostics; System Status Chirps; Table Of Zones - Viper 480XV Installation Manual

Car security
Hide thumbs Also See for 480XV:
Table of Contents

Advertisement

Diagnostics
The system's microprocessor monitors and reports all active and violated zones when arming and
disarming. LED flashes indicate the active or violated zone; siren chirps indicate system status.

Arm/Disarm Diagnostics

The number of siren chirps will indicate the status of the system when arming and disarming. For
information on which zone is active or has been violated refer to the Table of Zones .

System Status Chirps

Action
Number of Chirps
Arm
1
Arm
1 (3 second delay), 1
Disarm
2
Disarm
4

Table of Zones

Zone No.
Trigger type
1
Instant
2
Instant
3
Instant
4
Multiplexed Input 1
5
Progressive
6
Bonnet trigger
7
Multiplexed input 2
Note: The Warn Away
46
Description
System armed
System armed with Bypass Notification
System disarmed
System disarmed with Tamper Alert
Input description
H1/4 BLUE wire. Connect to boot pin switch.
On-board Ultrasonic sensors.
Door switch circuit. H1/3 GREEN or H1/5 VIOLET.
Inputs shorter than 0.8 seconds will trigger a
Warning Zone response, while inputs longer than
0.8 seconds will instantly trigger the full alarm
sequence.
Ignition input.
H1/6 GREY
Inputs shorter than 0.8 seconds will trigger a
Warning Zone response, while inputs longer than
0.8 seconds will instantly trigger the full alarm
sequence.
®
response on zones 4 or 7 do not report on the LED.
©
2005
Directed Electronics, Inc. all rights reserved

Advertisement

Table of Contents
loading

Table of Contents