Preinstallation Procedures; Ds4000 Fc2-133 Adapter Activity - IBM TotalStorage DS4000 FC2-133 Installation And User Manual

Dual port host bus adapter
Hide thumbs Also See for TotalStorage DS4000 FC2-133:
Table of Contents

Advertisement

Table 8. DS4000 FC2-133 Adapter activity
Green LED
Off
On
On
Off
Off
Flashing twice
per second
Off
The jumpers on the HBA set the default state of the laser and are set at the factory
with a jumper plug on pins 2-3 of the J3 and J4 jumpers.
Attention:

Preinstallation procedures

Complete the following tasks before you begin the installation:
v Read "Handling static-sensitive devices" on page 4.
v Read "What you need for the installation" on page 5.
v Write down the serial number of the DS4000 FC2-133. Each adapter has a
Amber LED
Off
On
Off
On
Flashing twice
per second
Flashing twice
per second
Flashing once
per second
Changing the jumper settings can result in the HBA being inoperable.
unique serial number. If the nonvolatile random access memory (NVRAM) (also
referred to as NOVRAM) is damaged, the system prompts you for the DS4000
FC2-133 serial number. Figure 3 on page 4 shows the location of the serial
number label.
Activity
Description
Power off
The server adapter is not
receiving power. The server is
powered off.
Power
The FC2-133 Adapter is receiving
power from the PCI or PCI-X slot
but is not initialized by the
adapter firmware.
Online
The FC2-133 Adapter is
successfully initialized by the
adapter firmware and is in a
ready state. The adapter firmware
is initialized when the adapter
BIOS code is loaded, Ctrl-Q is
pressed, or the operating system
driver is loaded.
Signal acquired
The FC2-133 Adapter firmware is
performing or waiting to perform
Fibre Channel loop initialization.
Loss of
The FC2-133 Adapter has
synchronization
detected a loss of synchronization
condition from the adapter Fibre
Channel receiver and is
attempting to resynchronize. A
loss of synchronization condition
might occur when a degraded
optical signal is received from the
LC-LC Fibre Channel cable or
optical interface connector.
Firmware error
The FC2-133 Adapter firmware
has detected an unrecoverable
error condition.
Beacon
The adapter is responding to a
Beacon command from a HBA
management program.
Chapter 1. Preparing and installing the DS4000 FC2-133
3

Advertisement

Table of Contents
loading