IBM ThinkCentre 8127 Hardware Maintenance Manual page 64

Ibm desktop computer hardware maintenance manual
Hide thumbs Also See for ThinkCentre 8127:
Table of Contents

Advertisement

58
Hardware Maintenance Manual
Diagnostic Error Code
015-027-XXX
USB port Configuration/Setup error
015-032-XXX
USB port Device Controller failure
015-034-XXX
USB port buffer
allocation failure
015-035-XXX
USB port Reset condition detected
015-036-XXX
USB port Register error
015-040-XXX
USB port IRQ failure
015-195-XXX
USB port Test aborted by user
015-196-XXX
USB port test halt, error threshold exceeded
015-197-XXX
USB port test warning
015-198-XXX
USB port test aborted
015-199-XXX
USB port test failed, cause unknown
018-000-XXX
PCI Card Test Passed
FRU/Action
1. Flash the system. See "Flash update
procedures" on page 148
2. System board
1. System board
1. Reboot the system
2. Flash the system and re-test. See "Flash
update procedures" on page 148
3. Run memory test
4. System board
1. Remove USB device(s) and re-test
2. System board
1. System board
1. Run setup and check for conflicts
2. Flash the system. See "Flash update
procedures" on page 148
3. System board
1. Information
2. Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 5, "Using the IBM Setup
Utility," on page 19
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 5, "Using the IBM Setup
Utility," on page 19
2. Flash the system and re-test. See "Flash
update procedures" on page 148
3. Go to "Undetermined problems" on page
89
1. Go to "Undetermined problems" on page
89
2. Flash the system and re-test. See "Flash
update procedures" on page 148
3. Replace component under function test
1. No action

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents