56
Hardware Maintenance Manual
Diagnostic Error Code
011-027-XXX
Serial port Configuration/Setup error
011-03X-XXX
011-04X-XXX
Serial port failure
011-195-XXX
Serial port Test aborted by user
011-196-XXX
Serial port test halt, error threshold exceeded
011-197-XXX
Serial port test warning
011-198-XXX
Serial port test aborted
011-199-XXX
Serial port test failed, cause unknown
011-2XX-XXX
Serial port signal failure
014-000-XXX
Parallel port Interface Test Passed
014-001-XXX
Parallel port Presence
014-002-XXX
014-003-XXX
Parallel port Timeout/Parity error
014-013-XXX
014-014-XXX
Parallel port Control Signal/Loopback test
failure
FRU/Action
1. Run Setup, enable port
2. Flash the system. See "Flash update
procedures" on page 148
3. System board
1. System board
1. Information
2. Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 5, "Using the IBM Setup
Utility," on page 19
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 5, "Using the IBM Setup
Utility," on page 19
2. Flash the system and re-test. See "Flash
update procedures" on page 148
3. Go to "Undetermined problems" on page
89
1. Go to "Undetermined problems" on page
89
2. Flash the system and re-test. See "Flash
update procedures" on page 148
3. Replace component under function test
1. External serial device
2. System board
1. No action
1. Remove external parallel device, if
present
2. Run setup, enable port
3. System board
1. System board
1. System board