IBM ThinkCentre 8127 Hardware Maintenance Manual page 59

Ibm desktop computer hardware maintenance manual
Hide thumbs Also See for ThinkCentre 8127:
Table of Contents

Advertisement

Diagnostic Error Code
001-278-XXX
System IRQ11 failure
001-279-XXX
System IRQ12 failure
001-280-XXX
System IRQ13 failure
001-281-XXX
System IRQ14
(hard disk drive) failure
001-282-XXX
System IRQ15 failure
001-286-XXX
001-287-XXX
001-288-XXX
System Timer failure
001-292-XXX
System CMOS
RAM error
001-293-XXX
System CMOS Battery
001-298-XXX
System RTC date/time update failure
001-299-XXX
System RTC periodic interrupt failure
001-300-XXX
System RTC Alarm failure
001-301-XXX
System RTC Century byte error
005-000-XXX
Video Test Passed
005-00X-XXX
Video error
005-010-XXX
005-011-XXX
005-012-XXX
005-013-XXX
Video Signal failure
005-016-XXX
Video Simple Pattern
test failure
005-024-XXX
Video Addressing test failure
FRU/Action
1. Device on IRQ11
2. System board
1. Device on IRQ12
2. System board
1. Device on IRQ13
2. System board
1. Hard disk drive cable
2. Hard disk drive
3. System board
1. Device on IRQ15
2. System board
1. System board
1. Run Setup and re-test
2. System board
1. Battery
2. System board
1. Flash the system. See "Flash update
procedures" on page 148
2. System board
1. System board
1. System board
1. Flash the system. See "Flash update
procedures" on page 148
2. System board
1. No action
1. Video card, if installed
2. System board
1. Video card, if installed
2. System board
1. Video Ram
2. Video card, if installed
3. System board
1. Video card, if installed
2. System board