50
Hardware Maintenance Manual
Diagnostic Error Code
000-039-XXX
BIOS DMI data error
000-195-XXX
BIOS Test aborted by user
000-196-XXX
BIOS test halt, error threshold exceeded
000-197-XXX
BIOS test warning
000-198-XXX
BIOS test aborted
000-199-XXX
BIOS test failed, cause unknown
000-250-XXX
BIOS APM failure
000-270-XXX
BIOS ACPI failure
001-000-XXX
System Test Passed
001-00X-XXX
System Error
001-01X-XXX
System Error
001-024-XXX
System Addressing test failure
001-025-XXX
System Checksum Value error
FRU/Action
1. Flash the system. See "Flash update
procedures" on page 148
2. System board
1. Information
2. Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 5, "Using the IBM Setup
Utility," on page 19
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 5, "Using the IBM Setup
Utility," on page 19
2. Flash the system and retest. See "Flash
update procedures" on page 148
3. Go to "Undetermined problems" on page
89
1. Go to "Undetermined problems" on page
89
2. Flash the system and re-test
3. Replace component under function test
1. Flash the system. See "Flash update
procedures" on page 148
2. System board
1. Flash the system. See "Flash update
procedures" on page 148
2. System board
1. No action
1. System board
1. System board
1. System board
1. Flash the system. See "Flash update
procedures" on page 148
2. System board

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents