Features Menu; Menu 1 - Avital 4003 Installation Manual

Directed electronics
Table of Contents

Advertisement

Features menu

The factory default settings are indicated in
low.

➢ Menu 1

Fea-
Feature
ture #
1
Honk pulses*
2
Ignition con-
trolled lock*
3
Ignition con-
trolled unlock*
4
Doorlock pulse
duration*
5
Unlock output*
6
Lock output*
7
Factory Alarm*
Disarm function
8
Factory Alarm
Disarm
9
Comfort
Closure*
10
Panic*
*Available only when adding a receiver (P/N 543H) and remote
(P/N 474L).
© 2009 Directed Electronics. All rights reserved.
Opt. 1
Opt. 2
Off
20 mS
Off
On
Off
On
0.8 sec.
3.5 sec.
1 pulse
2 pulses
1 pulse
2 pulses
with unlock.
Before un-
lock, remote
start only
1 pulse
2 pulses
Off
Comfort
Closure 1
On
Off
bold
text in the table be-
Opt. 3
Opt.4
30 mS
40 mS
0.4 sec.
Comfort
Closure 2
Opt. 5+
50 mS