PHYSICAL DATA (CONT.)
Indoor Unit 40MVC
System Voltage
Nominal Capacity (Btuh)
Operating Weight lb(kg)
Refrigerant Type
Metering Device
Charge (lb)
Indoor Fan
Rpm/Cfm (High)
Rpm/Cfm (Medium)
Rpm/Cfm (Low)
Motor (Watts / hp)
Blower Diameter ... Length (in)
Indoor Coil
Face Area (sq. ft)
No. Rows
Fins per inch
Circuits
Controls
Remote Controller
Fan Mode
Turbo Mode
Dehumidification Mode
Sleep Mode
Diagnostics
Timer Mode
Freeze Protection
Test Mode
Auto Restart
Auto Sweep
Control Voltage
Refrigerant Lines
Connection Type
Liquid Line (in) OD
Vapor Line (in) OD
Maximum Length ft(m)*
Max Lift (Fan Coil Above) ft(m)
Max Drop (Fan Coil Below) ft(m)
Condensate Drain
Size (in)
External Finish
* Refer to Long Line Application section on page 21
009
012
115
115 or 208/230
9000
12000
17.6(8)
25.3(11.5)
2.3(1.0)
2.9(1.3)
1250/325
1270/425
1000/260
1100/365
800/190
1000/340
20 / .034
25 / .044
3.84 ... 25.87
4.17 ... 25.2
2.15
2.54
2
19.5
19.5
2
Yes
Yes
13 VDC
13 VDC
1/4"
1/4"
3/8"
1/2"
65(19.8)
65(19.8)
35(10.7)
35(10.7)
35(10.7)
35(10.7)
.65 (OD) .53 (ID)
.65 (OD) .53 (ID)
White
White
8
018
208/230
18000
39.6(18)
R---410A
Capillary Tube at Outdoor
4.4(2.0)
1070/630
1000/570
960/500
31 / .075
4.21 ... 37.6
4.36
2
2
19.5
3
6
Integrated Microprocessor
Wireless
High/Medium/Low/Auto
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Pulse DC
Flare
1/4"
1/2"
100(30.5)
50(15.2)
50(15.2)
.65 (OD) .53 (ID)
White
024
208/230
24,000
39.6(18)
5.3(2.4)
1070/750
1000/660
960/585
50 / .112
4.21 ... 37.6
4.36
2
19.5
6
No
Pulse DC
3/8"
5/8"
100(30.5)
60(18.3)
60(18.3)
.65 (OD) .53 (ID)
White