POST Error Code
662 Configuration Change has occurred
6XX
Not listed above
762
Math coprocessor configuration error
7XX
Not listed above
962
Parallel port configuration error
9XX
1047
107X
Check SCSI terminator installation
1101
Serial connector error, possible system board
failure
1101, 1102, 1106, 1108, 1109
1107
1102
Card selected feedback error
1103
Port fails register check
1106
Serial option cannot be turned off
1107
1110
Register test failed
FRU/Action
1. Diskette drive configuration error or
wrong diskette drive type; run Setup.
1. Diskette Drive
2. System Board
3. Riser card
4. External Drive Adapter
5. Diskette Drive Cable
6. Power Supply
1. Run Setup.
2. Processor
3. System Board
1. Processor
2. System Board
1. Run Setup.
2. Parallel Adapter (if installed)
3. System Board
1. Printer
2. System Board
1. 16-Bit AT
Fast SCSI Adapter
1. Check SCSI terminator installation
2. SCSI Cable
3. SCSI Terminator
4. SCSI Device
5. SCSI Adapter
1. Run Enhanced Diagnostics
1. System Board
2. Any Serial Device
1. Communications Cable
2. System Board
1. Run Enhanced Diagnostics
1. Run Enhanced Diagnostics
2. System Board
1. Run Enhanced Diagnostics
2. System Board
1. Serial Device Cable
2. System Board
1. Run Enhanced Diagnostics
2. System Board
Chapter 7. Symptom-to-FRU Index