Q: Why does the GfCi trip immediately upon power up?
a:
1. If this is a new installation, make sure GFCI breaker is wired correctly. Refer to pages 8-13 .
2. Disconnect all the components (pumps, ozonator, and plug them back in one at a time to verify which
component is causing the GFCI to trip.
3. Check for any loose connections or cut wires in the box. If problem persists contact your dealer.
4. If running on 220V, make sure jumper from J11 to J32 is removed. See page 10.
Q: Why is my spa running all the time?
a: Check your filtration settings, you might be in continues filtration mode "Filc" or just set in a high filtra-
tion. Factory setting is F2 or Fil 2 which means your spa will filtrate 2 hours out of every 12 hours....twice a
day. If problem persists contact your dealer.
Q: What the ozonator does:
(The ozonator located inside your spa may either be a white or black box. See page 3.)
a: An ozonator purifies naturally. It reduces the need for high chemical doses, helps destroy bacteria, viruses,
algae and yeasts and oxidizes other contaminants to prolong equipment life. An ozonator reduces maintenance
time and cost.
Q: Why shouldn't I solely use an ozonator for water purification?
a: Ozone dissipates very quickly and cannot be measured over time. High ozone concentration is not good for
the spa's gaskets and seals. An ozonator used along with your favorite chemical system reduces the amount of
chemicals needed.
Q: What is the most efficient way to run my spa?
a: 220 volt is the most efficient voltage to run, because it takes less time to heat up the spa, which it will draw
less amps, and the spa will maintain temperature better than 110 volt. And factory settings for your filter cycle
2 hours out of every 12 hour period. 4 hours of filtration in a 24 hour period. Any further questions or concerns
please contact your dealer.