Control Panel Ident. (Barcelona 55, Vienna 66 And Madrid 77) - Strong Monaco 20 Owner's Manual

Acrylic spas
Table of Contents

Advertisement

CONTROL PANEL IDENTIFICATION
(BARCELONA 55, VIENNA 66 & MADRID 77)
system settings
When your spa is first actuated, it will go into Priming mode,
indicated by "Pr." The Priming mode will last for less than 5
minutes (press "Warm" or "Cool" to skip Priming Mode) and
then the spa will begin to take temperature readings, followed
by the heater test cycle. After completed, the heater will turn
on, heat the spa and maintain the water temperature in the
Standard mode.
The start-up temperature is set at 100°F/37°C. The
last measured temperature is constantly displayed on the LCD.
Note that the last measured spa temperature displayed is current
only when the pump has been running for at least 2 minutes.
To display the set temperature, press the "Warm" or
"Cool" pad once. Each press of the "Warm" or "Cool" pad will
continue to either raise or lower the set temperature. After three
seconds, the LCD will display the current spa temperature.
Jets 1
Touch the "Jets 1" button once to turn pump 1 on or off, and
to shift between low and high speeds. If left running, the low
speed of the pump will automatically turn off after 2 hours, and
the high speed will automatically turn off after 15 minutes.
Jets 2
Touch the "Jets 2" button once to turn pump 2 on or off and to
shift between low and high speeds. If left running, pump 2 will
automatically turn off after 15 minutes.
light
Press the "Light" button to turn the light on and off. If left on,
the light automatically turns off after 4 hours unless manually
turned off prior to 4 hours
mode
Mode is changed by pressing the "Warm" or "Cool" button,
then pressing the "Mode" button.
standard mode is programmed to maintain the desired tem-
perature. Note that the last measured spa temperature displayed
is current only when the circulation pump has been running for
at least 2 minutes. "Std" will be displayed momentarily when
you switch into Standard Mode.
economy mode heats the spa to the set temperature only dur-
ing filter cycles. "Ecn" will display solid when temperature is
not current, and will alternate with temperature when tempera-
ture is current.
sleep mode heats the spa to the set temperature only during
filtration cycles. "Slp" will display solid when temperature is
not current, and will alternate with temperature when tempera-
ture is current and will only heat to within 20 degrees of set
temperature.
option
The Option button is not used in any of our spas.
Preset filter Cycles
The first filter cycle begins 6 minutes after the spa is energized.
The second filter cycle begins 12 hours later. Filter duration is
programmable for 2, 4, 6, 8 hours or for continuous filtration
(indicated by "Filc"). The default filter time is 2 hours.
To program, press "Warm" or "Cool", then "Jets 1". Press
"Warm" or "Cool" to adjust. Press "Jets 1" to exit program-
ming. At the beginning of each filter cycle the pumps purge for
5 minutes. The only effect filter duration has is: 1) During the
filter cycle, the pump never turns off, and 2) In Economy and
Sleep Mode, heating only occurs during the filter cycle.
freeze Protection
If the temperature sensors detect a drop to below 44°F/6.7°C
within the heater, the pumps will automatically activate to pro-
vide freeze protection. The equipment stays on until 4 minutes
after the sensors detect that the spa temperature has risen to
45°F/7.2°C or higher.