CONTROL PANEL IDENTIFICATION
(MONACO 20 & 31, SEVILLE 22, EL DORADO 22 & BARCELONA 33)
system settings
When your spa is first actuated, it will go into Priming mode, indicated by "Pr." The Priming mode will last for less than
5 minutes (press "Warm" or "Cool" to skip Priming Mode) and then the spa will begin to take temperature readings, fol-
lowed by the heater test cycle. After completed, the heater will turn on, heat the spa and maintain the water temperature in
the Standard mode.
The start-up temperature is set at 100°F/37°C. The last measured temperature is constantly displayed on the LCD. Note
that the last measured spa temperature displayed is current only when the pump has been running for at least 2 minutes.
To display the set temperature, press the "Warm" or "Cool" pad once.
To change the set temperature, press the pad a second time before the LCD stops flashing. Each press of the "Warm" or
"Cool" pad will continue to either raise or lower the set temperature.
After three seconds, the LCD will stop flashing and display the current spa temperature.
Jets
Touch the "Jets" button once to turn the pump on or off, and to shift between low and high speeds. If left running, the low
speed of the pump will automatically turn off after 2 hours, and the high speed will automatically turn off after 15 min-
utes.
light
Press the "Light" button to turn the light on and off. If left on, the light automatically turns off after 4 hours unless manu-
ally turned off prior to 4 hours.

Preset filter Cycles

The first filter cycle begins 6 minutes after the spa is energized. The second filter cycle begins 12 hours later. Filter dura-
tion is programmable for 1-8 per 12 hours. The default filter time is 2 hours.
To program, press "Warm" then "Jets".
Press "Warm" to adjust. Press "Jets" to exit programming.
During the filter cycle, the low speed on the pump never turns off until filter cycle is completed, and in Economy and
Sleep Mode, heating only occurs during the filter cycle.