IBM TIVOLI ADSTAR 5697-VM3 User Manual page 27

Distributed storage manager for vm
Table of Contents

Advertisement

profile
link MAINT 51d 51d mr
access 51d d
vmfins install ppf 5654A09A {ADSM | ADSMSFS} (nomemo nolink
3
Execute the profile to access MAINT's minidisks.
4
If the Software Inventory disk (51D) was accessed R/O (read only) then
establish write access to the Software Inventory disk.
Note: If the MAINT 51D minidisk was accessed R/O, you will need to have
the user who has it linked R/W link it as R/O. You then can issue the
following commands to obtain R/W access to it.
5
Have the Tivoli ADSM for VM installation tape mounted and attached to
5654A09A at virtual address 181. The VMFINS EXEC requires the tape drive
to be at virtual address 181.
6
Install Tivoli ADSM for VM.
Notes:
a. If you've already created a PPF override file, you should specify your
override file name, in place of the default PPF name (5654A09A), after
the PPF keyword for the following VMFINS command.
b. You may be prompted for additional information during VMFINS INSTALL
processing depending on your installation environment. If you're unsure
how to respond to a prompt, refer to the Installing Products with
VMFINS and Install Scenarios chapters in the VMSES/E Introduction
and Reference to decide how to proceed.
Use ADSM for installing on minidisks or ADSMSFS
for installing in Shared File System directories.
The NOLINK option indicates that you don't want
VMFINS to link to the appropriate minidisks, only
access them if not accessed.
23
Installation Instructions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tivoli adstar

Table of Contents