General Data - Glow-worm COMPACT 100p Instructions For Installation And Operation Manual

Fanned flue combination boiler with honeywell gas control
Table of Contents

Advertisement

E
D
N
A
B
C
450
700
300
TABLE 1
Lift Weight
Total Weight
Gas connection
Heating and return
Domestic hot water
Safety valve
Safety valve discharge
Water content
I
Expansion vessel capacity 6 litres (1.32 gallons)
Heating cold fill
pressure minimum
D.H.W
working pressure
I
Maximum Heating
system water
content using
fitted expansion
vessel.
Electrical supply
Electrical rating
Internal Fuse rating
❋ Boiler starts at an inlet pressure of 0.5bar but
requires 0.8bar for maximum output.
I For larger systems use an additional expansion
vessel, see Section 4.

1 General Data

C
F
C L
FLUE
B
D
E
100
75
128
33.4kg (73.63b)
42.8kg (94.36lb)
Ø 15mm compression
Ø 22mm compression
Ø 15mm compression
Preset 3bar (43.5lbf/in
Ø 15mm copper
1.66 litres (0.37 gallon)
0.7bar
(10.1lbf/in
2
)
0.8 to 10bar
60 litres
(13.2 gallons)
with a cold
fill pressure
of 0.7bar
230V~50Hz
154W fused 3A
F1) Type T2A
F2) Type T315mA
A
G
M
C L
9mm
K
K
L
J
F
G
H
225
18
1.1 Installation
Materials and equipment should be fit for their purpose and of
suitable quality and workmanship.
1.2 Important Notice
This boiler is for use only on natural gas, G20.
1.3 Sheet Metal Parts
2
)
WARNING. When installing or servicing this boiler care should
be taken when handling the edges of sheet metal parts to avoid
any possibility of personal injury.
1.4 Requirements
The installation of this boiler must be carried out by a competent
person in accordance with the current rules in force in the
countries of destination at the time of installation.
Manufacturer's instructions, supplied.
Manufacturer's instructions must not be taken as overriding
statutory requirements.
1.5 Data Label
The data label is on the inner case cover, see diagram 1.2.
1.6 Data
See table 1 and diagrams 1.1, 1.2 & 1.3.
The Seasonal Efficiency Domestic Boilers UK (SEDBUK) is
71.6%.
The value is used in the UK Government's Standard Assessment
Procedure (SAP) for energy rating of dwellings. The test data
from which it has been calculated have been certified by B.S.I.
7
22mm COMPRESSION
CENTRAL HEATING
15mm COMPRESSION
DOMESTIC WATER
Rc 1 / 2 ( 1 / 2 in. BSPT)
GAS CONNECTION
H
J
K
L
135
65
110
Diagram 1.1
M
N
80
144
221680G