Download Print this page

Clifford GP500 Installation Manual page 15

Mobile security/convenience system
Hide thumbs Also See for GP500:

Advertisement

Five- Event To tal Re call
The system's nonvolatile memory records the identity of the last five
activated or malfunctioning triggers and sensors:
1. With the ignition off, press and hold the unmarked side of the
PlainView 2 switch.
2. Press remote control button 1 to arm the system, and then again
to disarm.
3. The LED will blink 1–5 times, pause, then blink 1–5 times, etc.
Write down the number of blinks in each cycle.
4. Refer to the chart below. The first number you wrote down was
the most recently activated trigger or sensor. The next number is
the second most recent, and so on up to as many as the last eight
activations.
LED flashes
Ignition switch was turned on while the system was
1 flash
armed
Activation of Digital Tilt/Motion Sensor
2 flashes
Activation of Dual-Level Piezo Sensor
3 flashes
In stal la tion Man ual/499
Meaning
13