Electrical Requirements - Emerson CORNERSTONE CF1AB01 Owner's Manual

Cornerstone series
Hide thumbs Also See for CORNERSTONE CF1AB01:
Table of Contents

Advertisement

This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
Tools Needed for Assembly
One Phillips head screwdriver
One wire stripper
One stepladder
Materials
Wiring outlet box and box connectors must be of type
required by the local code. The minimum wire would be
a 3-conductor (2-wire with ground) of following size:
Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capable
of withstanding a load of at least 50 pounds.
WARNING
!
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked "Acceptable for
Fan Support of 22.7kg. (50 lbs.) or less", and use
screws supplied with outlet box. Most outlet boxes
commonly used for support of light fixtures are not
acceptable for fan support and may need to be
replaced. Consult a qualified electrician if in doubt.
If your fan is to replace an existing ceiling light fixture,
turn electricity off at the main fuse box at this time and
remove the existing light fixture.
®
Your Cornerstone
ceiling fan comes with two sets of blade flanges. One set (consisting of two flanges)
allows you to use your fan with two blades, as the original 1895 Ceiling Fan was configured. The other set
(consisting of four flanges) allows you to use your fan with four blades. Both sets of flanges, and the fan
blades you selected, are patterned after the original 1895 Ceiling Fan. If your ceiling is nine feet or higher, you
may use the 18-inch downrod, along with the downrod trim and decorative bulb, to further enhance the 1895
ceiling fan look.
Install, Operate and Maintain Your Ceiling Fan

Electrical Requirements

Installed Wire Length
Up to 50 ft.
50-100 ft.
!
Before assembling your ceiling fan, refer to section on
proper method of wiring your fan (page 10). If you feel
you do not have enough wiring knowledge or
experience, have your fan installed by a licensed
electrician.
!
To avoid fire or shock, follow all wiring instructions
carefully.
Any electrical work not described in these
instructions should be done or approved by a licensed
electrician.
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring must
be in accordance with National and Local codes and
the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
4
Wire Size A.W.G.
14
12
WARNING
WARNING
WARNING
U.L. Model No.: CF1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents