4. Technical settings

4.3 Adjustments for over/undersized radiators

The factory setting is P2.
Use P1 if the radiator appears oversized for the room.
Use P3 if it is undersized.*
Press
for at least 3 seconds until
M is displayed.
Press
until Pb is displayed. Press
Select P1, P2 or P3 using the arrow keys,
and exit using
*The frequency of adjustment for P1, P2 and
P3 varies to compensate for radiator over/
under sizing.

4.4 Reset to factory settings

Remove the battery cover and take out one battery.
Press and hold
reinserting the battery.
Danfoss Link
Press OK.
Note that if the thermostat is moved to another room, it
is recommended it be reset to the factory default settings.
The thermostat will be reset and disconnected from
Danfoss Link
Danfoss Heating Solutions
for approx. 5 seconds, while
CC will then display "device removed".
TM
CC.
TM
UK
DE
DK
pb
NL
p2
11