Installation and operation
Global Error indicator (orange)
!
– Lights up orange if a prefailure event has been detected that
requires (precautionary) service intervention.
– Flashes orange if an error was detected that requires service
intervention.
– Does not light up if there is no critical event.
If the event is still acute after a power failure, the indicator is
activated after the restart.
The indicator also lights up in standby mode.
You can find more details on the indicated errors in the System
Event Log (SEL), on the ServerView Local Service Panel, on the
ServerView Local Service Display, in the ServerView Operations
Manager or via the iRMC S2's Web interface.
CSS
CSS indicator (yellow)
– Lights up yellow if a prefailure event was detected for a CSS
component that you can fix yourself (for reasons of
precaution) with the CSS concept.
– Flashes yellow if an error was detected that you can fix
yourself with the CSS concept.
– Does not light up when the system is OK.
If the event is still acute after a power failure, the indicator is
activated after the restart.
The indicator also lights up in standby mode.
For more information on the CSS concept, see
Service (CSS)" on page
ID
ID indicator (blue)
Lights up blue when the system has been selected by pressing the
ID button. To deactivate, press the button again.
The ID indicator can also be activated via the ServerView
Operations Manager and the iRMC S2 Web interface and its
status reported to the ServerView Operations Manager and the
iRMC S2.