Finalizing The Installation - Lopi Spirit Owner's Manual

Gas stove room heater
Hide thumbs Also See for Spirit:
Table of Contents

Advertisement

S
TOVE
Gas Inlet Location:
7 1/2" (from
center of stove)
Gas Pressure:
¥
¥
Purging the Gas Line:
The gas line must be properly purged to release all air in the gas line prior to starting the heater.

Finalizing the Installation

¥
¥
¥
¥
Note: See the instructions "Re-Routing the Power Cord to the Left or Rear of the Heater" in the optional
equipment section of this manual to re-route the power cord.
I
NSTALLATION
LOCATION OF THE
GAS INLET CENTER:
C L
HEIGHT:
From Base of Stove 1 1/2"
With Pedestal 12 3/4"
With Brass Legs 9 3/8"
With Cast Legs 9 3/8"
With Black Legs 8"
Natural Gas
Propane
If the pressure is not sufficient, make sure the piping used is large enough, the
supply regulator is adequately adjusted, and the total gas load for the residence
does not exceed the amount supplied.
The supply regulator (the regulator that attaches directly to the residence inlet or
to the propane tank) should supply gas at the suggested input pressure listed
above. Contact the local gas supplier if the regulator is at an improper pressure.
Before starting, all gas line joints must be leak tested.
Optional equipment must be installed (instructions are in the rear of this manual).
The ceramic logs must be placed inside the firebox (see the section "Installing the
Logs and Coals" in the maintenance section of this manual).
Start the heater and check for proper performance. Review the operations portion
of this manual to make sure the owner understands the operation of the heater.
(C
.) -
ONT
For qualified installers only!
Minimum Input Pressure
7" W.C.
11" W.C.
The 3/8" N.P.T. gas
inlet portrudes 1 1/2"
from the back edge of
the stove.
P
9
AGE

Hide quick links:

Advertisement

Table of Contents
loading