Nieco BroiVection JF143 Owner's Manual

Nieco BroiVection JF143 Owner's Manual

Natural gas/lp automatic broiler

Advertisement

roilVection
roilVection
Model JF143
Natural Gas/LP
Owner's Manual
A P P R O VA L S :
F O R Y O U R S A F E T Y:
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any
other appliance.
W A R N I N G :
Improper installation, adjustment, alteration, maintenance can cause property damage, injury, or
death. Read the installation, operating and maintenance instructions thoroughly before installing
or servicing this equipment.
Broiler area must be kept free of combustible materials, and the flow of combustion and ventilation
air must not be obstructed. Operating personnel must not perform any maintenance or repair
functions. Contact your Nieco Authorized Dealer.
IMPORTANT: RETAIN THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BroiVection JF143 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nieco BroiVection JF143

  • Page 1 Broiler area must be kept free of combustible materials, and the flow of combustion and ventilation air must not be obstructed. Operating personnel must not perform any maintenance or repair functions. Contact your Nieco Authorized Dealer. IMPORTANT: RETAIN THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE...
  • Page 2: Table Of Contents

    G. specifications ..........33 Nieco Corporation - Model JF143G...
  • Page 3: General Information

    Keep these instructions for future reference. If the unit changes ownership, be sure this manual accompanies the equipment. IMPoRTanT The nieco Corporation reserves the right to change specifications and product design. such revi- sions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
  • Page 4: Service/Technical Assistance

    Authorized Nieco Distributors and Service Agencies will void the warranty and may significantly alter the performance of your broiler. The use of non-Nieco parts is capable of affecting these criteria, and may affect broiler performance, parts longevity and food safety. Your local Authorized Nieco Distributor and Service Agent has been factory trained and has a complete supply of parts for your Nieco Automatic Broiler.
  • Page 5 Distributor for adjustment or repair. • Use only genuine Nieco replacement parts for your broiler. Failure to do so will void the warranty and may significantly alter the performance of your broiler. The use of non-Nieco parts is capable of affecting these criteria, and may affect broiler performance, parts longevity and food safety.
  • Page 6: Pre-Installation

    An adequate air supply must be available for safe and proper operation. For installations in the Commonwealth of Massachusetts the following shall apply: Venting shall be in compliance with NFPA Section 10.3.5.2 for the Model JF143. b.5 Clearance Keep appliance area free from combustibles.
  • Page 7: Gas Connection

    For easy movement of the appliance, the connector should be installed with a "lazy" loop for minimum tension. note: Gas appliances should be disconnected prior to maximum movement. (Minimal movement is possible to connect hose.) Nieco Corporation - Model JF143G...
  • Page 8: Restraining Device

    Disconnect power before servicing. b.10 Pre-operation Check Be sure that all parts are installed in the proper location: Ventilation is turned on Broiler is plugged in Gas line is connected Nieco Corporation - Model JF143G...
  • Page 9: Operation

    6. Bun Platen Temperature Control - Used to control the temperature of the bun platen. 7.Belt Reverse Button - Push and hold to reverse the direction of the belt to help clear a belt jam. Nieco Corporation - Model JF143G...
  • Page 10 The JF143 is equipped with automatic ignition. When the broiler is turned on, a hot surface ignitor turns on 5 seconds before the flow of gas. Gas then flows to all of the burners. If the burners are not lit within 10 seconds, the control will reset and try again for 10 seconds.
  • Page 11: Shutdown Procedure

    Your Nieco Automatic Broiler is designed to automatically stop gas flow to the broiler in the event of power failure, gas pressure loss or any other related incident. No attempt to operate this appliance should be made in the event of a power failure.
  • Page 12: Control Operation

    The control will then display the new set point for a few seconds, then display the actual tempera- ture. Under normal operation, when the platen is warming up, the control will display ‘Lo’, then it will display ‘Rdy’ when it is ready for use. Nieco Corporation - Model JF143...
  • Page 13 Adjust the levers up or down to increase or decrease the height of the bun platen for proper bun grilling. Nieco Corporation - Model JF143G...
  • Page 14 Picture of the part to be removed and cleaned. How to remove and Instructions clean the parts. Pull each meat guide out slightly from the bottom, then lift off. Wash, rinse, and sanitize in the 3-compartment sink. Nieco Corporation - Model JF143G...
  • Page 15 Scrub Pad 3-Compartment Sink Instructions Pull the release pin. Lift wire belt feeder bases up and off. Wash, rinse, and sanitize in the 3-compartment sink. REASSEMBLY: Pull the release pin and place feeder base in position. Nieco Corporation - Model JF143G...
  • Page 16: Grease Pan

    Make sure grease pan is cool before putting in water or it may warp the pans. Take to sink area and spray with degreaser. Wash with a scrub pad, rinse, and sanitize in the 3-compartment sink. Nieco Corporation - Model JF143G...
  • Page 17 REASSEMBLY: Slide the sheet back under the bun platen. Crumb Tray Clean: Daily Feed End Tools Scrub Pad 3-Compartment Sink Instructions Slide out from under bun belt. Wash, rinse, and sanitize in the 3-compartment sink. Nieco Corporation - Model JF143G...
  • Page 18 Discharge Heat Shield Clean: Daily Discharge End Tools Scrub Pad Heat Resistant Gloves Degreaser 3-Compartment Sink Instructions Lift up and off. Take to sink area and spray with degreaser. Wash, rinse, and sanitize in the 3-compartment sink. Nieco Corporation - Model JF143G...
  • Page 19 Clean: Daily Discharge End Tools Scrub Pad Heat Resistant Gloves Degreaser 3-Compartment Sink Instructions Lift sizzle plate up and off. Take to sink area and spray with degreaser. Wash, rinse, and sanitize in the 3-compartment sink. Nieco Corporation - Model JF143G...
  • Page 20 Make sure stripper blade is cool before putting in water or it may warp. Take to sink area and spray with degreaser. Wash with a scrub pad, rinse, and sanitize in the 3-compartment sink. REASSEMBLY: Hang stripper blade on brackets. Nieco Corporation - Model JF143G...
  • Page 21 Wash, rinse, and sanitize in the 3-compartment sink. Grease Chute Clean: Daily Discharge End Tools Scrub Pad Degreaser 3-Compartment Sink Instructions Lift up and off. Take to sink area and spray with degreaser. Wash, rinse, and sanitize in the 3-compartment sink. Nieco Corporation - Model JF143G...
  • Page 22 4. If necessary, use a stiff toothbrush to clean any clogged burner holes. REASSEMBLY: Be sure the holes on the burner are facing up. Burner must be completely dry before reassembly. Dry with a paper towel. Nieco Corporation - Model JF143G...
  • Page 23 EXTREMELY HOT! Be careful not to burn yourself. 1. Lift Incendalyst™ chimney up and off. 2. Take to sink area and spray with degreaser. 3. Wash with a scrub pad, rinse, and sanitize in the CAUTION: 3-compartment sink. Extremely Hot Nieco Corporation - Model JF143G...
  • Page 24 1. Lift air upper burner and air box from the top of the broiler. It is not necessary to detach them. 2. Use a stiff brush to clean any clogged burner holes. Be sure that both air box assemblies are installed and sit flush on their brackets. Nieco Corporation - Model JF143G...
  • Page 25 Screwdriver Instructions Clean pilot slots 1. From the discharge end of the broiler, remove the patty catch pan. 2. Use a flat head screwdriver or box cutter to clean the slots on the pilot orifices. Nieco Corporation - Model JF143G...
  • Page 26 Scrape each shaft of both belts on the discharge end with the wide end of the shaft cleaning tool. The tool is located on the clip on the back of the broiler. Wipe shaft cleaning tool with a towel. Nieco Corporation - Model JF143G...
  • Page 27: Troubleshooting

    Check cookout temperature (undercooking). CooKInG PRobleMs Burgers under or over cooked. Adjust conveyor belt speed. Clean burners and orifices. Excessive flaming in broiler. Clean the catalyst if equipped. Check the hood for proper operation. Check product for overcooking. Nieco Corporation - Model JF143G...
  • Page 28 PaRTs loCaTIon DRaWInGs Nieco Corporation - Model JF143G...
  • Page 29 SPROCKET, 35B32, Ø5/8“ BORE 21720 DRIVE SHAFT, BUN BELT, Ø5/8” X 22“ - WLDMT 20864 WIREBELT, FF, 15 X .092, 10.625W, 3SP, SLE, SS 21860 FRAME, ADJUSTING ARMS, BUN BELT - ASSY 21722 BEARING, Ø5/8” SHAFT, SIDE PANEL Nieco Corporation - Model JF143G...
  • Page 30 TRANSFORMER, 100-115-230VAC x 18-24VAC 16034 CONTROL TRANSFORMER 15480 MAIN ON/OFF SWITCH 12725 BRIDGE RECTIFIER 4418 RELAY (24V INPUT, 30V-25A OUTPUT) 13570-C CONTROL, LOAD SENSING, 1/16 DIN, 24V 17173 RAIL, POWER CONNECTION, 1Ø, 10MM - ASSY Nieco Corporation - Model JF143G...
  • Page 31 BRIDGE RECTIFIER 17185 SENSOR, FLAME, SLOTTED 16921 CONTROL, IGNITION, 24V 18861 THERMOCOUPLE PROBE 1.88 TYPE J 48“ LEADS 13727-B MOTOR CONTROL 18447 BLOWER, HIGH PRESSURE, 24VDC, 2 WIRE 13570-C CONTROL, LOAD SENSING, 1/16 DIN, 24V Nieco Corporation - Model JF143G...
  • Page 32: Wiring Diagrams

    H. WIRInG DIaGRaM M ot or R ever se Sw i t ch P/ N 13579 Nieco Corporation - Model JF143G...
  • Page 33 H. WIRInG DIaGRaM Nieco Corporation - Model JF143G...
  • Page 34: Specifications

    CaUTIon Do not operate the broiler at gas pressures other than those stated here. Doing so will affect the opera- tion of your broiler. Nieco Corporation - Model JF143G...
  • Page 36 Updated: Wiring diagram; cleaning procedures 11-8-2012 Added parts location drawing and parts replacement list nieco Corporation 7950 Cameron Drive Windsor, CA 95492 (707) 284-7100 Office • (707) 284-7430 Fax www.nieco.com • e-mail: service@nieco.com Printed in the USA © 2011 Nieco Corporation All Rights Reserved...

Table of Contents