1 . Unplug the saw .
2 . Turn the height-adjusting handle to
raise the blade all the way .
3 . Place a mark beside one of the blade
teeth at the front of the blade . Place
the body of a combination square
against the miter gauge groove, and
measure the distance from the blade
tooth to the right miter gauge groove,
as shown in Fig . 29 .
4 . Turn the blade so that the marked tooth
is at the back .
5 . Move the combination square to the
rear, and measure the distance from the
blade tooth to the right miter gauge
groove again . If the distances are the
same, the blade and the miter gauge
groove are parallel .
Page 21
ASSEMbLy
If the distances are different:
1 . Loosen adjusting bolts (1) and (2) using
the included 15/64" (6 mm) hex key .
NOTICE: The adjusting bolts are located
under the saw table at the front of the saw .
Turn adjusting bolt (3) and (4) left or right
until the blade is square; securely retighten
adjusting bolts (1) and (2) .