3 . Retighten the locking knob and push
the stop pin in .
To check the angle indicator:
Loosen the locking knob and place a 90º
square against the miter gauge rod and the
miter gauge base to verify that the angle
indicator is at 0º . If it is not, loosen the
locking screw on the rod using a Phillips
screwdriver (not included) to adjust the
angle indicator to 0º, and then retighten
the locking screw .
USING THE SLIDING EXTENSION
TAbLE (FIG. 19)
FIG. 19
Increase the length of the saw table by using
the extension table .
1 . Set the rip fence to 12 1/2" (31 .8 cm) .
2 . Push the extension-table locking lever
toward the back to unlock the lever .
3 . Slide the extension table to the desired
width .
NOTICE: Use the scale on the extension rail
when a specific width is desired .
4 . Once the extension table is set to the
desired width, re lock the lever by pulling
the lever forward .
ASSEMbLy
Extension table
ALIGNING THE bLADE TO THE
MITER GAUGE GROOVE
(FIG. 20-21)
FIG. 20
Right Miter
Gauge Groove
FIG. 21
1
3
WARNING:
square so that the wood does not bind,
resulting in kickback. Failure to do so
could result in serious personal injury.
Do
not
loosen
adjustment until you have checked with
a square and made test cuts to be sure
adjustments are necessary . When the
screws are loosened, these items must be
reset .
Combination
square
2
4
The blade must be
any
screws
for
Page 20
this