*Recommended filter sizes for field---installed air filter grilles mounted on the wall or ceiling of the conditioned structure. Required filter sizes shown are based on
the larger of the ARI (Air Conditioning and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 ft (91.4 m) /minute for throwaway type
or 450 ft (137 m) /minute for high ---capacity type. Air filter pressure drop for non ---standard filters must not exceed 0.08 in. wc.
A- -Weighted Sound Power Level (dBA)
MODEL
Sound Ratings
50XL
(dBA)
024
75
030
75
036
75
042
75
048
78
060
78
NOTE: Tested in accordance with ARI Standard 270 ---95 (not listed in ARI).
024
2
363
(165)
10.1
(kg)
(4.6)
2 Ton
EA36DY129
2...21
13.6
2700
22
559
1/8 (825)
3...17
3.7
Comfort
Variable based on Comfort Settings (see User Interface instructions for more information).
Efficiency
700
Max
800
10x10
(254x254)
1/2
20x24x1
(508x610x25)
(mm)
Typical Octive Band Spectrum (dBA without tone adjustment)