Carrier Infinity 50XL Product Data page 2

15 seer single-packaged system with puron (r-410a) refrigerant single phase 2-5 nominal tons (sizes 024-060)
Hide thumbs Also See for Infinity 50XL:
Table of Contents

Advertisement

be damaged due to corrosion. They are ideal for seacoast
applications.
Thermostatic Expansion Valve—A hard- -shutoff, balance- -port
TXV maintains a constant superheat at the evaporator exit (cooling
cycle) resulting in higher overall system efficiency.
High- - and Low- -Pressure Switches give added safety and
reliability to the compressor.
Low sound ratings ensure a quiet indoor and outdoor
environment with sound ratings as low as 75 dBA. (See page 3.)
Easy to service cabinets provide easy single- -panel accessibility to
serviceable components during maintenance and installation. The
basepan, with integrated drain pan, provides easy ground level
installation with or without a mounting pad. Convenient handholds
are provided to manipulate the unit on the job site. A nesting
feature ensures a positive basepan to roof curb seal when the unit is
roof mounted. A convenient 3/4- -in. (19 mm) wide perimeter
flange makes frame mounting on a rooftop easy.
TABLE OF CONTENTS
FEATURES/BENEFITS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MODEL NUMBER NOMENCLATURE
ARI CAPACITIES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PHYSICAL DATA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPTIONS AND ACCESSORIES
BASE UNIT DIMENSIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ACCESSORY DIMENSIONS
SELECTION PROCEDURE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PERFORMANCE DATA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TYPICAL PIPING AND WIRING
APPLICATION DATA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ELECTRICAL DATA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TYPICAL WIRING SCHEMATICS
CONTROLS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GUIDE SPECIFICATIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Louvered grille provides hail and vandalism protection for the
coil.
Cabinets are constructed of heavy- -duty, phosphated, zinc- -coated,
pre- -painted steel capable of withstanding 500 hrs of salt spray.
Interior surfaces of the evaporator and electric heater compartments
are insulated with cleanable semi- -rigid insulation board, which
keeps the conditioned air from being affected by the outdoor
ambient temperature and provides improved indoor air quality.
(Conforms to American Society of Heating, Refrigeration and Air
Conditioning Engineers No. 62P.) The sloped drain pan minimizes
standing water in the unit, which is provided with an external
drain.
Short- -cycling protection for the compressor is incorporated into
our Infinity heat pump/air conditioner dual capacity control board
ensuring a five- -minute delay before restarting compressor after
shutdown for any reason.
Limited Warranty—Standard 5- -year limited warranty on all
parts, 10- -year limited warranty on compressor.
2
1- -2
3
3
4
5- -6
7- -8
9
10
11- -18
19
20
20
21
22
23- -24

Hide quick links: