Troubleshooting - Silvercrest SEM 1100 A2 Operating Instructions Manual

Espresso machine sem 1100 a2
Table of Contents

Advertisement

Troubleshooting

GB
IE
Problem
The espresso no
longer fl ows out
the espresso drips over
the edges of the sieve
carrier w instead of
from the openings.
The espresso is cold.
Noisy operation
of the pump.
18
Cause
• The espresso powder is too
moist and/or compressed
too tight.
• No water in the water tank 1.
• The holes in the sieve carrier
openings are blocked.
• The sieve carrier w is not
correctly inserted.
• The sieve carrier openings
are blocked.
• There are espresso powder
residues on the edges of the
sieve carrier w.
• The appliance was not
preheated.
• The green heating-up control
lamp 4 has not yet glowed.
• The cups were not prewarmed.
• The water tank 1 is empty.
• The water tank 1 is not properly
inserted, meaning that water
cannot enter into the appliance.
Remedy
• Reprepare the espresso, however,
this time do not compress it so
tightly, or exchange it completely.
• Fill the water tank 1 with water.
• Clean the sieve carrier w.
• Correctly insert the sieve carrier
w.
• Clean the sieve carrier w.
• Clean the espresso powder
residues from the edges of
the sieve carrier w.
• Preheat the appliance.
• Wait until the green heating-up
control lamp 4 glows.
• Prewarm the cups.
• Fill the water tank 1 with water.
• Correctly insert the water tank 1.