Supermicro SUPERSERVER 6016T-URF4+ User Manual page 120

Table of Contents

Advertisement

S
S
UPER
ERVER 6016T-URF4+/6016T-NTRF4+ User's Manual
Serverboard
X8DTU-LN4F+ (Proprietary form factor)
Dimensions: 14.85 x 12.68 in (377 x 322 mm)
Chassis
SC819TQ-R700U (1U rackmount)
Dimensions: (WxHxD) 19 x 1.7 x 27.75 in. (483 x 43 x 705 mm)
Weight
Gross Weight: 38.5 lbs. (17.5 kg.)
System Cooling
Five 4-cm counter-rotating fans (FAN-0086L4)
System Input Requirements
AC Input Voltage: 100-140 VAC
Rated Input Current: 8.5-6A
Rated Input Frequency: 50 to 60 Hz
AC Input Voltage: 180-240 VAC
Rated Input Current: 5-3.8A
Rated Input Frequency: 50 to 60 Hz
Power Supply
Rated Output Power: 700W (Part# PWS-703P-1R)
Rated Output Voltages: +12V (58A), +5Vsb (3A)
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 20% to 95% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
B-2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Superserver 6016t-ntrf4+

Table of Contents