1-6-5 Fuser unit

(1) Detaching and refitting the fuser unit
<Procedure>
1. Remove the outer covers. See page 1-6-2.
2. Remove the two connectors.
3. Remove the wire from two clamps.
4. Pull out the rear cover axis (with spring)
from the axis hole ( ) on side.
5. Pull out the rear cover axis from the axis
hole ( ) on side and remove the rear cover
and the spring.
Clamp
Connector
Wire
Clamp
Axis hole
Spring
Axis
Rear cover
Connector
Figure 1-6-12
Axis
Spring
Figure 1-6-13
2GL/2FV/2FW
Axis hole
1-6-9