1-5-2 Self-diagnosis

(1) Self-diagnostic function
When a self diagnostics error occurs, the printer halts and displays the appropriate error code using a combination of the
READY and ATTENTION indicators.
LED indicator
ATTENTION indicator (Amber)
READY indicator (Green)
Example: self-diagnostic code: E6 (F050)
Indicates the
occurrence of a self
diagnostics error.
ATTENTION
7.3 s
READY
Self-diagnostic code conversion table
Self-diagnostic code
4 digits
2 digits
6400
A0
7980
D9
7990
DA
F040
E0
2000
E1
4000
E2
4200
E3
6000
6010
E4
6050
F050
E6
F010
F1
F020
F2
F030
F3
The ATTENTION indicator means 1 when it flashes in synchronization with the
READY indicator which flashes at the interval of 1.2 second; and it means 0 when it
turns off: This is repeated 8 times. Two digit self diagnostics codes are indicated in 8
bits (2 digits hexadecimal) using the ATTENTION indicator.
Interval
1
2.4 s
ATTENTION indicator
1
0
1
0
0
1
1
0
1
1
1
1
0
1
1
1
1
1
0
0
1
1
1
0
0
1
1
1
0
0
1
1
1
0
0
1
1
1
0
0
1
1
1
0
0
1
1
1
1
0
1
1
1
1
0
1
1
1
1
0
Figure 1-5-3 Self-diagnostic code indication
Indication example
Lit
Off
Lit
Off
E
(Hexadecimal)
1
1
0
0
0
0
0
0
1
0
1
0
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
1
0
0
0
1
16/18 ppm printers only
0
1
0
0
1
1
6
0
1
1
Remark
2GL/2FV/2FW
0
Repeat
1-5-3

Hide quick links: