Swing indicator
Displayed during up / down movement of the
louver.
10
Set temperature display
The selected set temperature is displayed.
11
Remote controller sensor indicator
Displayed when the remote controller sensor is
used.
12
Pre-heat indicator
Displayed when the heating mode is energized or
defrost cycle is initiated.
While this indication is displayed, the indoor fan
stops or operate in fan mode.
13
No function indicator
Displayed when the function requested is not
available on that model.
14
Fan speed indicator
Indicates the selected fan speed:
(Auto)
(High)
(Medium)
(Low)
15
Louver Number display
(exapmle:01, 02, 03, 04)
16
Louver lock indicator
Displayed when a louver is locked. (4-way
cassette type only)
17
UNIT No. display
Displays the number of the indoor unit selected.
Also displays error code of indoor and outdoor
units.
13-EN
17
18
1
7
8
9
10
11
12
14
18
Central control indicator
Displayed when the air conditioner is controlled
centrally and used with central control devices
such as the central remote controller.
If the use of the remote controller is prohibited by
the central control,
blinks when the ON /
OFF, MODE, or TEMP. button on the remote
controller is pushed, and the buttons do not
function. (Settings that can be configured on the
remote controller differ depending on the mode of
the central control. For details, read the Owner's
Manual of the central remote controller.)
19
Operation mode controlled indicator
Displayed when MODE button is pushed while
operation mode is fixed to cool or heat by the air
conditioner administrator.
20
Operation ready display
This display appears on some models.
21
Service display
Displayed while the protective device works or a
trouble occurs.
– 7 –

Operation section

Once the settings have been configured, all you need to do is push the
19
20
13
1
button (Fan speed select button)
Selects the desired Fan speed.
* Not available for the concealed duct high static
pressure and fresh air intake type. Only "High" is
displayed.
2
button (Timer set button)
Use to setup the timer.
3
button (TEST button)
Use only for service.
(During normal operation, do not use this button.)
4
button
Use when a ventilator (commercially-available) is
connected. Push the button to turn on / off the
ventilator. Turning on / off the air-conditioner also
turns on / off the ventilator.
No ventilator is connected if "
*
the remote controller display after pushing the
button.
5
button (Filter reset button)
Resets "
FILTER" indication after cleaning.
6
button (Power save operation)
No function.
7
SWING/FIX
button
Use to select automatic swing or fixed louver
position.
* Not available for concealed duct, slim duct, floor
concealed and floor standing cabinet fresh air
intake types.
1 8
12
2
5
3
7
6
8
Operation lamp
Lights up during running.
Blinks when an error occurs or the protective
device activates.
9
Turns on the unit when pushed, and turns off when
pushed again.
10
Selects desired operation mode.
" appears on
button from then on.
9
10
4
11
button
button (Operation mode select button)
14-EN