Step 2: Setting The Time; Iron And Manganese Tank Regen; Testing Chlorine Levels In Water - Pelican WF6 Owner's Manual

Iron/manganese filter & salt free softener
Hide thumbs Also See for WF6:
Table of Contents

Advertisement

Pelican WF6/WF10 Iron/Manganese Filter and Salt Free Softener
4. Follow the steps in the table below to finish setting the valve. When each setting is displayed, use
the UP and DOWN buttons to scroll to the appropriate data setting displayed in the table. Press
EXTRA CYCLE to select the data setting and go to the next setting.
Table 5: Setting the Valve
Parameter Display (Left Corner)
VT (Valve Type)
CT (Control Type)
DO (Day Override)
RT (Regeneration Time)
BW (Backwash)
RR (Rapid Rinse)

Step 2: Setting the Time

1. Press and hold down the UP button to change the clock.
2. Press the EXTRA CYCLE button when the time is set. The water valve displayed will stop flashing
when the time is set.

Iron and Manganese Tank Regen

!IMPORTANT!
You will not be able to use water in the house for approximately 25 minutes during the Regen process.
1. Press and hold the EXTRA CYCLE button for 3 seconds.
Note: Gears will make noise and water will start to flow.
2. Allow the system to EXTRA CYCLE for 25 minutes.
Your manual regen cycle is complete and the tank is ready for use.
Note: The days between regen may vary based on flow and Iron content. If you are unsure about the
days between regen please contact your Pelican dealer for further help.

Testing Chlorine Levels in Water

1. Put the carbon tank in bypass.
2. Turn on the nearest cold water faucet to the system.
3. Listen and watch the pump to make sure it is pumping. The pump should pulse and not run
continuously. If the water is off, the pump will stop.
4. Let the water run for 10 minutes.
5. After 10 minutes, use the chlorine test strip at the running cold water faucet to check the chlorine
level.
6. The optimum chlorine level reading is 3ppm on the test strip.
a.
If the level is lower than 3ppm chlorine, remove the black clip from the ratio adjustment
slide. Turn the ratio adjustment slide 2 full revolutions in the positive direction. Replace the
black clip.
b.
If it is higher than 3ppm, remove the black clip from the ratio adjustment slide. Turn the
ratio adjustment slide 2 full revolutions in the negative direction. Replace the black clip.
© 2013 Enviro Water Solutions, Inc.
3060 Performance Circle, Suite 2, DeLand, FL 32724
Data Display Set To
Fltr
tc
3
2:00
10
10
Rev P
Page 19
www.pelicanwater.com
(877) 842-1635

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wf10

Table of Contents