Pelican WF6/WF10 Iron/Manganese Filter and Salt Free Softener

Product Operation and Specifications

Specification Description
Max Flow Rate*
Minimum Working Pressure
Maximum Working Pressure
Maximum Vacuum
Operating Temperatures
pH Range
*Minimum Rated Service Flow must be at least 6 GPM.

Important Information

Read these instructions carefully and determine the location of all system components before
beginning installation.
Check all applicable plumbing, building, and electrical codes for installation compliance.
Install the system on the main water supply.
Systems that contain electronic components cannot be installed outside in uncovered areas.

Water Conditions for Operation

The water should be free of hydrogen sulfide, a dissolved gas with a characteristic smell of rotten
eggs. If present, it can coat the catalytic surface of the media and interfere with the process. The gas
should be removed through adequate pre-treatment.
The water should be free of hydrocarbons, oils, and lubricants. If present, they can coat the catalytic
surface of the media and interfere with the process. Remove through adequate pre-treatment.
The water should contain less than 1 mg/l of phosphates. Phosphates sequester dissolved hardness
molecules preventing them from forming crystals and may coat the catalytic media surface and
interfere with the process.
The copper level in the water supply should be below the MCL of 1.3mg/L. If copper is present above
this level, it can attach to the surface of the catalytic media and interfere with the process.
WARNING:
If this or any other system is installed in a metal (conductive) plumbing system, i.e. copper or
galvanized metal, the plastic components of the system will interrupt the continuity of the
plumbing system. As a result any errant electricity from improperly grounded appliances
downstream or potential galvanic activity in the plumbing system can no longer ground
through contiguous metal plumbing. Some homes may have been built in accordance with
building codes, which actually encouraged the grounding of electrical appliances through the
plumbing system. Consequently, the installation of a bypass consisting of the same material
as the existing plumbing, or a grounded "jumper wire" bridging the equipment and re-
establishing the contiguous conductive nature of the plumbing system must be installed prior
to your systems use.
CAUTION:
When adding a filtration/softening system to homes/buildings supplied by well water, the system should be
installed following the pressure tank. DO NOT USE this system for pneumatic or hydro pneumatic
applications. If you are using a booster pump, then install this system following the booster
pump. If you have questions, please call customer service.
© 2013 Enviro Water Solutions, Inc.
3060 Performance Circle, Suite 2, DeLand, FL 32724
WF6
10 GPM
25 PSI
80 PSI
5 inch/127 mm Hg
36°F – 120°F
7 - 11
WF10
15 GPM
www.pelicanwater.com
(877) 842-1635
Rev P
Page 4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wf10