System Fault Handling - Example; Cantrak Loss Of Display - Seastar Solutions Optimus 360 Operating Instructions & User Manual

Joystick control system for outbord powered vessles
Hide thumbs Also See for Optimus 360:
Table of Contents

Advertisement

This area shows the
active faults
Describes what system has
done to react to fault
Tells the User how
to proceed
© 2012 SeaStar Solutions
10.2.4
System Fault Handling – Example
The following is an example of how the system would respond to the
warning fault hazard of a low port engine battery.
The CANtrak display will enter the warning screen mode and pulse the
system warning buzzer. The three warning screen zones will appear
as shown below.
Figure 10-7. Sample warning fault.
The system status zone informs the user that the second station
joystick is not working. The fault handling instruction zone tells the
user to use another control device and seek technical support.
The vessel should be returned to port immediately for repair.

10.2.5 CANtrak Loss of Display

If CANtrak display operation is lost proceed as follows:
1. On a multiple helm station vessel each station may be equipped
with a CANtrak display. If so equipped, navigate from another helm
station and immediately return to port for service.
2. If there are no secondary displays on board, carefully verify (at low
speed) that the steering system and shift and throttle operates
normally then immediately and cautiously proceed to port for service.
Optimus 360 User's Manual, Rev. C
Active Fault
Description Zone
System Status Zone
Fault Handling
Instructions Zone
10-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents