Irrigation water should be directed away from the
heat pump pool heater-water spray can damage
the heat pump pool heater.
Rain water run offs- the heat pump pool heater
can withstand normal rain. Install rain gutters to
prevent direct steams of rain water to the heat
pump pool heater.
It is important to keep the area next to the heat
pump pool heater clear of shrubs, bushes and
chemicals containers. They could prevent air from
circulating fully through the heat pump pool heater,
and will affect the operation of the heat pump pool
heater or damage the heat pump pool heater.
When installed in areas where freezing tempera-
tures can be encountered, drain the water circuit
to prevent possible freeze-up damage. See the
Freeze Protection Section.
For high wind installation requirements, refer to
the diagram on page 8.

Electrical Connections

Refer to the unit rating plate below the control panel for
precise power requirements for your unit, and for
ampacity and over-current protection requirements.
AIR FLOW OUT
3 FT
MIN
AIR
FLOW
IN
Fig. 1: Installation Clearances
7
60"
MIN
12"
MIN
AIR
FLOW
IN
All wiring must be in accordance with the National
Electrical Code, NFPA No. 70, latest edition, and all
applicable state and local codes. Wiring diagrams are
located on pages 21 through 26.
NOTE: Refer to the National Electrical Code, Article
680, for general requirements for swimming pools
and equipment, and to Article 440 for special consid-
erations necessary for circuits supplying hermetic
refrigeration motor/compressors.
Locate the equipment disconnect means within 3
feet of the heater's electrical enclosure, or as
close to the heater as possible. Always satisfy
applicable codes and standards.
In sizing power wiring, be especially aware of up-
sizing requirements necessary due to wiring
distances. Always satisfy applicable codes and
standards.
Electrical installation should be done by a licensed
electrician only.
This unit is pre-wired to work with external control sys-
tems, heat-on-demand options and other external time
clock overrides. Refer to the external control system's
instructions, and page 27 of this manual, for installa-
tion information.