Water Connections; Pressure Drop - Raypak 5350 Series Installation & Operating Instructions Manual

Heat pump pool & spa heater
Table of Contents

Advertisement

Model No.
5350
6350/6350HC
8350/8350HC

Water Connections

CAUTION: The heat pump pool heater inlet and
outlet connections are NOT interchangeable. They
must be connected as instructed below.
1. Connect the heat pump pool heater in the return
water line between the filter and the pool/spa. See
the Plumbing Diagrams beginning on page 16.
2. Connect the filter outlet to the fitting marked
WATER IN at the bottom front of the unit.
3. Connect the fitting marked WATER OUT to the
return piping to the pool/spa. Unit inlet/outlet con-
nection fittings are 2-inch PVC unions.
Water connections from the unit to the main return
line can be PVC pipe or flexible pipe approved for
the purpose and, in either case, should be at least
equal in size to the main pool/spa circulation pip-
ing.
Flow
(gpm)
Note: Multiply the pressure drop in psi by 2.3067 to yield the pressure drop in Ft. H
VAC in - Phase - Hz
208/230 - 1 - 60
208/230 - 1 - 60
208/230 - 1 - 60
208/230 - 3 - 60
Table A: Typical System Electrical Power Requirements
5350
30
4
40
7
50
10
60
11
70
12
80
13
Table B: Pressure Drop Across Heat Pump Pool Heater
Minimum Circuit
Ampacity (A)
40.0
42.0
42.0
34.0
WATER IN
Fig. 2: Water Connections
4. In cold weather (freeze zone) areas, shutoff valves
(ball or gate type) must be installed at the unit inlet
and outlet to facilitate service and cold weather
drain-down.
5. Operate the pump and check the system for leaks.

Pressure Drop

For system pressure drop information, refer to Table B
below.
Pressure Drop (psi)
6350/6350HC
6
9
10
11
12
13
9
Maximum Breaker
Size (A)
60
60
60
50
WATER OUT
8350/8350HC
9
9
10
11
12
13
O Head (TDH).
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6350 series6350hc series8350 series8350hc series8360

Table of Contents