Raypak 5300 Owner's Manual

Swimming pool heat pump

Advertisement

This manual should be maintained in legible condition and kept
adjacent to the heat pump or in a safe place for future use.
The instructions in this manual are for the use of qualified individuals specially
trained and experienced in the installation and maintenance of this type of
equipment and related system components. Installation and service personnel
are required by some states to be licensed.
Persons not qualified shall not attempt to install, service, or maintain this
equipment.
Developed and printed in U.S.A.
For additional information call: (800) 260-2758
The Pool and Spa Heating Experts
Manual Effective Date: 6/24/2005
Raypak
Swimming Pool
®

Heat Pump

OWNER'S MANUAL
Models
5300
6300
8300
R
C
US
9900276
Part No. 00-02107A

Advertisement

Table of Contents
loading

Summary of Contents for Raypak 5300

  • Page 1: Heat Pump

    This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use. For additional information call: (800) 260-2758 The instructions in this manual are for the use of qualified individuals specially trained and experienced in the installation and maintenance of this type of equipment and related system components.
  • Page 2 Please read these signs and labels, as they convey important safety information about hazards that may be potentially present in and around the heat pump. They are classified according to relative seriousness of the hazard potential, from DANGER as the most serious, to WARNING, to CAUTION as the least serious.
  • Page 3: Table Of Contents

    VII. Heat Pump Running Time........
  • Page 4: Introduction

    As with all pool heat pumps, compared to other types of heat pumps such as gas- or oil-fired, this heat pump has lower heating capacity on a BTU/hr basis. As a result, it will be required to operate longer to accomplish the desired results. It may, at certain times, operate as much as 24 hours per day.
  • Page 5: Electrical Connections

    Situate the pool heat pump carefully to minimize installation costs while providing maximum efficiency of operation, and to allow adequate service access, as follows: • For unrestricted air intake and service access, position each side of the unit at least 1 ft (30 cm) from walls, pipes and other obstructions.
  • Page 6: Water Connections

    The heat pump inlet and outlet connections are NOT interchangeable. They must be connected as instructed below. 1. Connect the heat pump in the return water line between the filter and the pool/spa. See page 10, Plumbing Diagrams. 2. Connect the filter outlet to the fitting marked 3.
  • Page 7 • Power (amber lamp): When lit, indicates power is applied to the unit. NOTE: The heat pump will not run when the Remote position is selected on the Pool/Spa selector switch and there is no remote control system attached. •...
  • Page 8: System Start-Up

    NOTE: At the beginning of the heating season, or whenever the pool water temper- ature is to be raised several degrees, the pool pump and heat pump may need to operate continuously for several days. During summer months, only a few hours per day may be necessary, or none at all.
  • Page 9: Heat Pump Running Time

    VIII. Summer Shutdown If you do not plan to use the heat pump during the summer months, secure and protect it as follows: 1. From the control panel, turn the control switch to 2.
  • Page 10: Maintenance

    XI. Troubleshooting If your heat pump does not operate, or simply does not heat your pool water, the indicator lamps on the front control panel (see Section IV) can provide valuable clues as to what is wrong, and may even indicate precisely what the problem is.
  • Page 11 Normally, it takes about 4 days. How many hours per day is the unit operating? Remember that the heat pump only operates while the pool pump is running. Set the time clock to permit 24 hour per day operation.
  • Page 12: Service Call Verification

    Use a pool chemistry test kit to confirm there is no chlorine in the condensation. Or, b. Shut the heat pump OFF and leave the filter pump running to see if the water stops dripping. If the water stops dripping, the heat pump is not leaking.
  • Page 13: Plumbing Diagrams

    For systems with pumps of 2 HP or greater (over 80 gpm), an external bypass is required. Adjust the bypass valve to divert a minimum of 40 gpm through the heat pump. Connections are 2-inch unions. Plumb the heat pump after the filter and before any chlorinators.

This manual is also suitable for:

63008300