Initial Starting &Operating - Quincy Compressor QR-25 Series Instruction Manual

Hide thumbs Also See for QR-25 Series:
Table of Contents

Advertisement

Step 12)
On watercooled
units, open the water valve to fill the cooling
system,
Check for leaks.
If a manual water valve is used, adjust the valve to maintain
an adequate
flow of water.
If a water temperature
regulator valve is used, install a small bypass orifice
in front of the regulator
valve to allow heated water to circulate
around the
temperature
sensing bulb at all times.
Step 13)
After all the above conditions have been satisfied, the unit can be
connected to the proper power source.
Step 14)
Jog the starter switch to check the rotational
direction
of the
compressor.
It should agree with the rotation arrow embossed on
the compressor
sheave,
. .
Step 15)
Check for proper rotation of the cylinder cooling fan (fins inside
sheave).
The fan should blow cooling air across the cylinder.
Initial Starting & Operating
This instruction
manual, as well as any instructions
supplied by manufactur-
ers of supporting
equipment,
should be read and understood
prior to starting
the compressor.
If there are any questions regarding
any part of the instruc-
tions, please call your local Quincy Distributor,
or the Quincy
Compressor
factory.
With the pre-starting
checklist completed
and satisfied, start the compres-
sor. Watch and listen for excessive vibration and strange noises. If either exist,
stop the compressor.
Refer to SECTION
6,
Troubleshooting
for help in
i%X 1068
Fig. 4-1
Oil Pressure
Adjustment
determining
the cause of such problems.
If you are starting a pressure lubricated
model, check the oil pressure.
Compressors
producing
up to 250 p.s.i.g. of discharge
air pressure should
maintain
18 to 20 p.s.i.g. of oil pressure.
High pressure rated compressors
producing more than 250 p.s.i.g. of discharge air pressure should maintain
22 to 25 p.s.i.g. of oil pressure.
Normally the oil pressure does not need to be adjusted.
But if it does,
loosen the locknut on the adjustment
screw located on the left side of the oil
pump housing (see Fig. 4-1, Oil Pressure
Adjustment).
Increase the oil
pressure
by turning
the adjustment
screw clockwise;
decrease
the oil
pressure by turning the adjusting
screw counterclockwise.
After adjust-
ment tighten the locknut.
Check the air receiver pressure
gauge or system pressure
gauges for
proper readings.
If inadequate
or excessive air pressure conditions
exist, refer
to Section
6 Troubleshooting.
Observe compressor
operation
closely for the first hour of operation
and
then frequently
for the next seven hours. After the first eight hours, monitor
the compressor
at least once every eight hours. If any abnormal conditions
are
witnessed,
stop the compressor
and correct the problem.
After two days of
QR-25 Series
QUINCY COMPRESSOR
52201-104
16
February
1994