Daily Starting Checklist - Quincy Compressor QR-25 Series Instruction Manual

Hide thumbs Also See for QR-25 Series:
Table of Contents

Advertisement

..
-.—.... . .
—.
----
... . - .. . .. ,-.. ..-.——.
————
operation check belt tension, oil level, and inspect the system for leaks.
Daily Starting
Checklist
Do not proceed until the Pre-starting
Checklist
and Initial Starting
&
Operating
sub-sections
have been read and are thoroughly
understood.
Step 1)
Step 2)
Step 3)
Step 4)
Step 5)
Step 6)
Step 7)
Step 8)
Step 9)
Check oil level in crankcase.
Drain liquid from the air receiver and moisture trap (if so equipped).
Turn on cooling water (watercooled
units)
Jog the starter button and check compressor
rotation.
Note:
Continuous
Run Units - Prior to starting a continuous
run unit,
pull the ring attached to the pilot valve out and turn the finger nut
in (clockwise)
until it seats against the pilot housing.
Now the
compressor
can be started
unloaded.
Once the compressor
is
running at full speed, the finger nut on the pilot valve can be turned
out (counterclockwise)
until it seats against the pull ring.
Start compressor
per factory instructions.
(Refer to SECTION
4,
Pre-Starting
Checklist
and Initial Starting&
Operating. )
Check system pressure.
Check cooling fan.
Check all pressure relief valves for proper operation,
Check control system for proper operation.
QR-25 Series
QUINCY
COMPRESSOR
52201-104
17
February
1994

Advertisement

Table of Contents
loading

Table of Contents