Flashes
Fault message
2
No loop signal
3
No drive
3
Upside down
3
Trapped
8. TROUBLE SHOOTING
Cause
The loop
generator/charger is not
connected to the mains
supply or its miniature
circuit-breaker has
tripped.
Boundary wire broken.
The connection
between Automower
and the charging station
has been lost.
This may be due to the
boundary wire being
routed in the wrong
direction around an
island, which blanks out
the signal.
If this occurs in isolated
areas it may be due to
interference from
metallic objects
(perimeter fence,
reinforcement bar) or
buried cables in the
vicinity.
Automower has got
caught in something.
Automower leans too
much or has turned
over.
Automower has got
caught in something.
Action
Check the wall socket connection
and whether the miniature
circuit-breaker has tripped.
Reset the miniature circuit-breaker
by removing the loop
generator/charger's power cord
from the wall socket, wait 10
seconds and then reconnect the
power cord in the wall socket again.
Check the signal given by the LED
on the loop generator/charger. If it
flashes the loop is damaged. Repair
the broken cable using an original
waterproof coupler.
Link the mower to the loop
generator/charger by changing the
PIN code, see page 31. You can
use the same PIN code as earlier.
You can use the same PIN code as
earlier.
Check that the boundary wire has
been routed correctly.
Try moving the boundary wire.
Free the mower and rectify the
reason for the lack of drive. If it is
due to wet grass, wait until the lawn
has dried before using the mower.
Turn the mower the right way up.
Free Automower and rectify the
reason for it getting trapped.