Reading The Front Panel Indicators - Xantrex PROwatt SW 700i Owner's Manual

Sine wave inverter
Table of Contents

Advertisement

Operation

Reading the Front Panel Indicators

Indicator LEDs
If the Green LED is On, it indicates that the unit is On and the
AC outlet has power.
If the Red LED is On, it indicates that the AC outlet has no
power due to an error condition and an error code is displayed
on the digital display underneath the LED.
If the Red LED is blinking, it indicates that the unit is still On
but with a warning condition and an error code is displayed on
the digital display.
Digital Display
Under normal operating conditions, the digital display shows
the input voltage (in volts) and the output power (in kilowatts).
Under an error condition, the digital display shows an error
code and the Red LED turns on.
Under a warning condition, the digital display shows an error
code and the Red LED blinks.
16
Description of LED and Digital Display Codes
LED
Digital Display
1.3.5.
Green
1.4.3.
Green
0.2.5.
a.L.1.
Green
a.L.0
Green
E.0.1.
Red
E.0.2.
Red
E.0.3.
Red
E.0.4.
Red
E.0.5.
Blinking
Red
E.0.6.
Blinking
Red
E.0.7.
Blinking
Red
Xantrex PROwatt™ SW International Sine Wave Inverter Owner's Guide
Description
Example: 13.5 volts
Example: 1.43 Kw (1,430 watts)
Example: 0.25 Kw (250 watts)
Alarm is set to Enabled
Alarm is set to Disabled
Under voltage shutdown
Over voltage shutdown
Over load shutdown
Over temperature shutdown
Under voltage alarm warning
AC Out over load warning
Over temperature warning

Hide quick links: