Detailed Programming
NOTE: When the J-PACK Series dimmer pack is powered up, the menus are "LOCKED!!" with
access only to the basic system configuration menus, which includes setting the DMX
start address as well as enabling or disabling the end-of-line DMX termination. The
menus need to be "UNLOCKED" to access the advanced system configuration menus.
To toggle between "LOCKED!!" and "UNLOCKED" press and hold down the EXECUTE
and then ESCAPE switches at the same time for 4-5 seconds.
The sequence of the following system configuration menu items appear as the MENU DOWN (
switch is pressed. Pressing the MENU UP (
menu items in the opposite order. Pressing and holding either of the MENU UP/DOWN (
switches will speed up the scroll rate, which can be helpful to speed up the configuration time.
Basic Menus
ADDRESS
1.
DMX>001
DMX>512
DMX>001
DMX TERM
2.
ENABLED
DISABLED
18
of System Configuration Menu Items
Set the DMX start address.
The DMX start address can be assigned from 001 to 512.
Press EXECUTE to enter the menu.
Displays the current DMX start address for both DMX inputs.
Press MENU (
) to modify and select the desired DMX start address.
Press both MENU (
) simultaneously to toggle to DMX start address 001.
Press ESCAPE to exit the menu and save the selected DMX start address.
Press RESET to exit the menu without saving.
The menu will automatically timeout after 2 minutes of inactivity and save.
NOTE: DMX O/P must be set to OFFSET mode for this menu to function.
Enable or disable the DMX termination.
Activates and deactivates a 120Ω termination resistor. DMX termination is indicated
on the LCD display when DMX is being received. When the DMX input is not
terminated (DISABLED) the LCD display will read XXX. When the DMX input is
terminated (ENABLED) the LCD display will read XXX TERM.
Press EXECUTE to toggle termination from ENABLED to DISABLED.
Press EXECUTE to toggle termination from DISABLED to ENABLED.
Any change in the configuration is automatically saved.
NOTE: Ensure only the last (end-of-line) DMX receiving device is terminated!