Output Connector/Receptacle Options

J-PACK Series dimmer packs are designed for high performance dimming of standard
incandescent, quartz, and dimmable (SCR/Leading-Edge) electronic low-voltage fixtures. The
dimmer outputs may be configured for non-dimmed applications when switched (relay controlled)
load outputs are required. Six (6) 1,560 Watt dimmer output circuits are fully protected by
premium 13 Amp hydraulic magnetic circuit breakers. Each of the dimmer outputs are connected
via various optional output connectors/receptacles.
120VAC Operation with Factory Installed Single or Dual Edison Power Cord
Capable of dimming six (6) 1,560 Watt dimmer output circuits, fully protected by premium 13 Amp
hydraulic magnetic circuit breakers. Powered with single or dual 120VAC 1Ø 3-Wire, each hot leg
is dimmed independently through six (6) Solid State Relays (SSR). J-PACK Series dimmer packs
supplied with a factory installed single (1) Edison power cord are capable of dimming a total of
1,800 Watts shared between the six (6) Duplex Edison output connectors. J-PACK Series dimmer
packs supplied with factory installed dual (2) Edison power cords are capable of dimming a total
of 3,600 Watts shared between the six (6) Duplex Edison output receptacles.
120VAC Output Receptacle with Factory Installed Single or Dual Edison Power Cord
ED = 15A Duplex Edison (NEMA 5-15)
120VAC Operation
Capable of dimming six (6) 1,560 Watt dimmer output circuits, fully protected by premium 13 Amp
hydraulic magnetic circuit breakers. Powered with 120/240VAC 1Ø 4-Wire or 120/208VAC 3Ø
5-Wire, each hot leg is dimmed independently through six (6) Solid State Relays (SSR). Capable
of dimming a total of 9,000 Watts shared between the six (6) output connectors/receptacles.
120VAC Output Connector/Receptacle Options
SP = 20A Stage Pin (Bates)
TL = 20A Twist Lock Ground (TLG) (NEMA L5-20R)
SO = 19-Pin Socapex
TB = Terminal Block
19-Pin Socapex Connection Details (Pinout)
10
Pin 1 = Circuit 1 Hot
Pin 2 = Circuit 1 Neutral
Pin 3 = Circuit 2 Hot
Pin 4 = Circuit 2 Neutral
Pin 5 = Circuit 3 Hot
Pin 6 = Circuit 3 Neutral
Pin 7 = Circuit 4 Hot
Pin 8 = Circuit 4 Neutral
Pin 9 = Circuit 5 Hot
Pin 10 = Circuit 5 Neutral
WWW.JOHNSONSYSTEMS.COM
Pin 11 = Circuit 6 Hot
Pin 12 = Circuit 6 Neutral
Pin 13 = Circuit 1 Ground
Pin 14 = Circuit 2 Ground
Pin 15 = Circuit 3 Ground
Pin 16 = Circuit 4 Ground
Pin 17 = Circuit 5 Ground
Pin 18 = Circuit 6 Ground
Pin 19 = Not Used