Quick Programming Reference To System Configuration Menu Items - JOHNSON SYSTEMS J-PACK Series User Manual

Hi-performance dimmer pack
Hide thumbs Also See for J-PACK Series:
Table of Contents

Advertisement

Quick Programming Reference
Basic Menus
ADDRESS
1.
Set the DMX start address.
DMX TERM
2.
Enable or disable the DMX termination.
Advanced Menus
3.
SCENESET
Enable and setup 6 different backup scenes.
4.
FADETIME
Set the fade time for each of the 6 scenes from 0 to 99 seconds.
5.
SNAPSHOT
Record DMX levels into the backup scenes.
6.
DIM TEST
Test the dimmer outputs one at a time, or all at once.
7.
MONITOR
View the control level to each dimmer output.
8.
DMX O/P
Configure the on-board DMX protocol manager for offset or patch mode.
9.
DMX PAT
Patch each of the 6 dimmer (PWM) outputs to any DMX input channel.
10. SH TIME
Set the DMX status hold time from 0 to 99 minutes or infinite.
11. DC PATCH
Configure the dimmer to channel patch for the dimmer pack.
12. DIM CURV
Configure the dimmer curve for each output.
13. VOUT LIM
Set the maximum RMS output voltage for each dimmer.
14. REGULATE
Enable or disable the dimmer output voltage regulation.
15. STANDBY
Enable or disable the power savings standby mode.
16. TEST INC
Set the test increment units to percent or hexadecimal.
17. SCENEMOD
Enable or disable scene mode.
18. AUX TEST
Test the auxiliary dry-contact inputs.
19. AUX1MODE
Set the auxiliary input 1 mode to activate a selected scene or load shed.
20. AUX2MODE
Set the auxiliary input 2 mode to activate a selected scene or load shed.
21. LOADSHED
Select dimmers to be disabled (turned off) by the auxiliary inputs.
22. Ø-PATCH
Set the zero-cross phase reference for each dimmer control output circuit.
23. WARMING
Turn the "lamp warming" feature on or off.
24. V-RANGE
Set the supply voltage range for 120 Volts or 240 Volts operation.
25. LINE V
View the RMS line voltage for each power phase.
26. LINE F
View the line frequency of phase A.
27. REM TEMP
View the temperature of the remote temperature sensor.
28. CTL TEMP
View the temperature of the microcontroller.
29. RTIME
View the total run time of the microcontroller.
30. HARD-KEY
View the microcontroller's unique eight-character hard-key code.
31. SERIAL#
View the microcontroller's unique eight-character silicone serial number.
32. VERSION
View the microcontroller's firmware version.
33. DEFAULTS
Set various system configuration settings to the factory default.
34. LED INT
Set the LED intensity for the programming switches.
35. LCD VIEW
Adjust the contrast of the LCD Display for optimum viewing.
WWW.JOHNSONSYSTEMS.COM