Feature Setting - Nature Power 38330 Owner's Manual

3000w pure sine inverter charger
Table of Contents

Advertisement

Estimated Run Times
Following run times are estimates for reference, based on using different battery bank sizes.
Actual run times may vary.
AC Load
50 W
100 W
200 W
500 W
1000 W
1500 W
2000 W
2500 W
3000 W
Note: N.R. – Not Recommended

5. FEATURE SETTING

To understand more about the unit features, read the following section and follow the instructions
to make changes to the desired setting.
Feature Menu for Unit Setting
To enter feature setting mode, on remote display, press and hold 'EXIT' button for 5 seconds.
The feature setting menu will display on the screen with the following sequence:
Menu Sequence
Charger
Inverter
SCR set
Power Save
Battery Type
Set Current
EQ Mode
(Flooded battery
type use only)
Fault Alarm
Brightness
Backlight Timer
Use the '+' and '-' button to scroll between feature setting menu.
Press 'ENTER' button to go to the selected feature and you can now make changes on the
selected feature to your desired setting.
Use the '+' and '-' button to scroll between different set values or setting. Once the desired values
or setting is chosen, press 'ENTER' button to save the setting or press 'EXIT' button to quit the
setting without saving.
 
 
Estimate run time on different 12V Battery Bank Size
60AH
120AH
11 hrs.
22 hrs.
5 hrs.
11.5 hrs.
2.5 hrs.
5 hrs.
49 mins
2 hrs.
15 mins
49 mins
8 mins
27 mins
N.R.
15 mins
N.R.
11 mins
N.R.
N.R.
Setting
On/Off
On/Off
15, 20,25,30 A
0, 5, 10, 15, 20, 50W
AGM, GEL, Flooded
60 – 150A (5A step)
On/Off
On/Off
10-100% (10% step)
1–9 mins (1 min step)
Page 13
180AH
240AH
33 hrs.
44 hrs.
17 hrs.
23 hrs.
8 hrs.
11 hrs.
3 hrs.
4 hrs.
1.5 hrs.
2 hrs.
49 mins
1 hr
34 mins
49 mins
25 mins
37 mins
17 mins
27 mins
Function
Turns Battery Charger On/Off
Turns Power Inverter On/Off
Set AC Input Source Power Breaker Rating.
During by-pass mode with high demand for
AC power for the load, the charger current is
reduced automatically to prevent the tripping
of the AC Source power breaker.
Lowers power draw when low power loads are
connected to inverter
Select battery type
Set charger current
EQ mode is used to equalize the flooded
battery. The charging voltage is 16V and the
current is set to half the set bulk current for 1
hour (min: 30A, Max: 75A).
Silent mode: Enable or Disable the audible
alarm when fault occur
Set LCD Background lighting brightness
Set timer ON for LCD background lighting
 
 
300AH
55 hrs.
29 hrs.
13.5 hrs.
5 hrs.
2.5 hrs.
1.5 hrs
1 hrs
49 mins
37 mins