Nature Power 38330 Owner's Manual page 11

3000w pure sine inverter charger
Table of Contents

Advertisement

Fault
Push Button Functions on Unit
A beeping sound will occur every time that any button on the unit is triggered.
Button
Power
Reset
Push Button Functions on Remote Display
A beeping sound will occur every time any button on the unit is triggered.
Button
O
Enter
+
-
EXIT
Understanding the Charger Functions
Three-Stage Charging:
The Three-Stage Charging algorithm has a Bulk, then Absorption and then Float sequence.
During the Bulk stage, the battery accepts the maximum constant current from the charger. In
the Absorption stage, the battery voltage is held to constant voltage and the charging will
slowly reduce. In Float stage, the charger continuously produces voltage at a lower level to
fully top up the battery and maintain the battery in a fully charged state.
The charger will automatically restart the charging cycle in Bulk stage if the battery is
discharged to 12.5V. Also, after seven days, the charger will automatically restart the
recharging cycle to refresh the battery.
Battery Type:
Three types of battery setting (GEL, AGM and Flooded) are available. See reference battery
charging voltage as shown:
Battery Type
GEL
AGM
Flooded
Equalize the Flooded Battery:
For Flooded battery type, equalization mode is available. Use the following procedure to
equalize the flooded battery. See also section 5 on setting EQ mode for flooded battery.
DANGER: Explosion Hazard. The flooded battery generates explosive gases
during equalization. Follow all the battery safety precautions listed in the manual.
CAUTION:
 
 
Green
Pass-Through Mode (AC mode). Battery Charging is in progress.
LED
Remote LCD Display shows:
ON
- Battery DC Voltage and charging current
(flashing)
- AC Input Voltage and Current
e.g. AC: 120V
Press '+' or '-' key to check charging stage.
e.g.
Press '+' or '-' key to check AC Input Power.
e.g.
Red
Unit has shutdown. Display shows error code and error message.
LED ON
- Low battery shutdown
e.g. FAULT:
(solid)
Turns unit On/Off. Press and hold for 1 second to turn unit On/Off
Reset the unit: Press once to reset the unit. This may be required when an error
is detected on the unit
Turns LCD display On/Off. Press and hold for 2 seconds to turn display On/Off.
Display shows unit model number and revision.
Nature
38330
e.g.
Power
REV 1.1
Save the selected setting or go to the next stage
Scroll up on the menu
Scroll down on the menu
Exiting or entering the feature setting mode
Absorption
14.4 V
14.3 V
14.4 V
Risk of Battery and Equipment damage. Only a Flooded lead-acid battery can
20A
DC: 12.0V
Charge Stage ABS
System Power
2.4 KW
E01
Low Battery
Function
Function
Float
13.8 V
13.45 V
13.5 V
 
Page 11
 
50A
Equalization
N.A.
N.A.
16.0 V

Hide quick links: