Technical Data - GE ZIC36ON Series Technical Service Manual

Monogram bmnf refrigerators with electronic controls
Table of Contents

Advertisement

TECHNICAL DATA

DISCONNECT POWER CORD BEFORE SERVICING
IMPORTANT - RECONNECT ALL GROUNDING DEVICES
All parts of this appliance capable of conducting
electrical current are grounded. If grounding wires,
screws, straps, clips, nuts or washers used to
complete a path to ground are removed for service,
they must be returned to their original position and
properly fastened.
CAUTION
To avoid personal injury when servicing the
condensing unit, stand on a ladder which will give
enough support to allow removal of the top panel
and safely allow access to service the unit.
ELECTRICAL SPECIFICATIONS
Max Defrost Control
W/No Door Openings .................... 60 hrs. @ 40 min
Evap Defrost Thermo Disc ............................... 65-45°F
Light Thermostat. .......................................... 190-130°F
Electrical Rating: 115V. AC 60 Hz. ................... 9.0 amp
Maximum Current Leakage ............................. 0.50 mA
Maximum Ground Path Resistance .......... 0.14 Ohms
Energy Consumption ................................ 571 KWhr/yr
NO LOAD PERFORMANCE
CONTROL POSITION 37-0°F and
AMBIENT TEMPERATURE OF
Fresh Food, °F .............................. 36-42 ............... 34-40
Frozen Food, °F ........................... (-3) -3 .............. (-3) -3
Percent Running Time ................. 25-37 ............... 45-57
REFRIGERATION DIAGNOSIS
To access the low pressure side of the system, install a
WR86X0097 valve only on the process tube extending
from the compressor case.
TO CABINET
WIRING
RED
ORANGE
BLACK
RUN
CAPACITOR
70°F
90°F
OVERLOAD
C
S
R
2
3
RELAY
GREEN
(GROUND)
IMPORTANT SAFETY NOTICE
This information is intended for use by individuals
possessing adequate backgrounds of electrical,
electronic and mechanical experience. Any attempt
to repair a major appliance may result in personal
injury and property damage. The manufacturer or
seller cannot be responsible for the interpretation
of this information, nor can it assume any liability
in connection with its use.
REFRIGERATION SYSTEM
Compressor ................................................. 830 BTU/hr
Minimum Compressor Capacity
Vacuum, ..................................................... 26 inches
Minimum Equalized Pressure
@ 70°F .......................................................... 71 PSIG
@ 90°F ........................................................ 104 PSIG
R134a Refrig. Chg. ................................................ 13 oz
REPLACEMENT PARTS
Temperature Control ............................... WR55X10098
Relay ......................................................... WR07X10033
Overload .................................................. WR08X10022
Run Capacitor (15 uF) ............................... WR62X0080
Lamp Overtemperature Thermostat ..... WR50X10003
Defrost Heater Overtemperature
Thermostat ........................................... WR50X10030
Defrost Heater ......................................... WR51X10015
Condenser Fan Motor ............................. WR60X10053
Condenser Fan Blade .............................. WR60X10049
Evaporator Fan Motor ............................ WR60X10043
Evaporator Fan Blade ............................. WR60X10050
Main Board .............................................. WR55X10056
Thermistors (2-FF, 1-FZ, 1-EV) ................ WR55X10028
Drain Pan Fan Motor ............................... WR60X10051
Damper .................................................... WR09X10065
Evaporator ............................................... WR85X10007
Compressor ............................................. WR87X10041
Condenser ................................................ WR84X10030
Dryer ........................................................... WR86X0096
– 3 –